« Volver al listado

Dlink

Dlink Dir-816 A2 Firmware: vulnerabilidades y CVE

Dlink Dir-816 A2 Firmware tiene 13 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 12 son críticas y 0 figuran en el catálogo de explotación activa de CISA.

CVE13
Últimos 12 meses0
Críticas12
Explotadas activamente0

Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología

Últimas vulnerabilidades

CVESeveridadEPSSExplotación activaPublicadaDescripción
CVE-2025-44835Media (6.3)1.1%—1 may 2025
D-Link DIR-816 A2V1.1.0B05 was found to contain a command injection in iptablesWebsFilterRun, which allows remote attackers to execute arbitrary commands via shell.
CVE-2024-0921Crítica (9.8)38%—26 ene 2024
A vulnerability has been found in D-Link DIR-816 A2 1.10CNB04 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/setDeviceSettings of the component Web Interface.…
CVE-2023-43240Crítica (9.8)13%—21 sept 2023
D-Link DIR-816 A2 v1.10CNB05 was discovered to contain a stack overflow via parameter sip_address in ipportFilter.
CVE-2023-43239Crítica (9.8)13%—21 sept 2023
D-Link DIR-816 A2 v1.10CNB05 was discovered to contain a stack overflow via parameter flag_5G in showMACfilterMAC.
CVE-2023-43238Crítica (9.8)1.3%—21 sept 2023
D-Link DIR-816 A2 v1.10CNB05 was discovered to contain a stack overflow via parameter nvmacaddr in form2Dhcpip.cgi.
CVE-2023-43237Crítica (9.8)13%—21 sept 2023
D-Link DIR-816 A2 v1.10CNB05 was discovered to contain a stack overflow via parameter macCloneMac in setMAC.
CVE-2023-43236Crítica (9.8)1.1%—21 sept 2023
D-Link DIR-816 A2 v1.10CNB05 was discovered to contain a stack overflow via parameter statuscheckpppoeuser in dir_setWanWifi.
CVE-2018-17068Crítica (9.8)3.7%—15 sept 2018
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction in the handler function of the /goform/Diagnosis route. This could lead to command…
CVE-2018-17067Crítica (9.8)1.9%—15 sept 2018
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. A very long password to /goform/formLogin could lead to a stack-based buffer overflow and overwrite the return address.
CVE-2018-17066Crítica (9.8)7.3%—15 sept 2018
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction in the handler function of the /goform/form2systime.cgi route. This could lead to command…
CVE-2018-17065Crítica (9.8)1.9%—15 sept 2018
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. Within the handler function of the /goform/DDNS route, a very long password could lead to a stack-based buffer overflow and overwrite the return address.
CVE-2018-17064Crítica (9.8)7.4%—15 sept 2018
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/sylogapply route. This could lead to command…
CVE-2018-17063Crítica (9.8)4.1%—15 sept 2018
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/NTPSyncWithHost route. This could lead to…

Otros productos de Dlink