« Back to list

Codesys

Codesys Control FOR Iot2000: vulnerabilities and CVEs

Codesys Control FOR Iot2000 has 12 published vulnerabilities, 0 of them in the last 12 months. 3 are rated critical and 0 are listed by CISA as actively exploited.

CVEs12
Last 12 months0
Critical3
Actively exploited0

All vulnerabilities in the catalogue →⭐ Follow this technology

Latest vulnerabilities

CVESeverityEPSSActive exploitationPublishedDescription
CVE-2018-25048High (8.8)1.0%—Mar 23, 2023
The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device.
CVE-2020-12069High (7.8)0.16%—Dec 26, 2022
In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local…
CVE-2020-15806High (7.5)2.0%—Jul 22, 2020
CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation.
CVE-2020-12068Medium (6.5)0.94%—May 14, 2020
An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation.
CVE-2020-10245Critical (9.8)2.5%—Mar 26, 2020
CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.
CVE-2020-7052Medium (6.5)1.9%—Jan 24, 2020
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition.
CVE-2019-18858Critical (9.8)1.9%—Nov 20, 2019
CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.
CVE-2019-13542Medium (6.5)1.4%—Sep 17, 2019
3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may…
CVE-2019-9009High (7.5)1.7%—Sep 17, 2019
An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.
CVE-2019-9008High (8.8)1.9%—Sep 17, 2019
An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime.
CVE-2019-13548Critical (9.8)5.8%—Sep 13, 2019
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote…
CVE-2019-13532High (7.5)3.2%—Sep 13, 2019
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller.