Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2663▼ 380 respecto a la semana anterior
Críticas / altas1289▼ 36 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)244▼ 274 respecto a la semana anterior
–

12 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)1.1%—Lexmark X950 FirmwareLexmark X952 FirmwareLexmark X954 FirmwareLexmark X940e Firmware+809/3/202016/6/2026
Lexmark X, W, T, E, C, 6500e, and 25xxN devices before 2011-11-15 allow attackers to obtain sensitive information via a hidden email address in a Scan To Email shortcut.
ModificadaCrítica (9.8)4.1%—Windriver VxworksBelden Hirschmann HiosBelden Garrettcom Magnum Dx940e FirmwareSiemens Ruggedcom Win7000 Firmware+314/8/201917/6/2026
Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and 7 has Incorrect Access Control in the RARP client component. IPNET security vulnerability: Handling of unsolicited Reverse ARP replies (Logical Flaw).
ModificadaCrítica (9.8)9.0%—Windriver VxworksSonicwall SonicosSiemens Siprotec 5 FirmwareNetapp E-series Santricity OS Controller+99/8/201917/6/2026
Wind River VxWorks 6.7 though 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 3 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion during connect() to a remote host.
ModificadaCrítica (9.8)23%—Windriver VxworksSonicwall SonicosSiemens Siprotec 5 FirmwareNetapp E-series Santricity OS Controller+99/8/201917/6/2026
Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 2 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion caused by a malformed TCP AO option.
ModificadaAlta (7.5)23%—Windriver VxworksSonicwall SonicosSiemens Siprotec 5 FirmwareNetapp E-series Santricity OS Controller+89/8/201917/6/2026
Wind River VxWorks 6.6 through vx7 has Session Fixation in the TCP component. This is a IPNET security vulnerability: DoS of TCP connection via malformed TCP options.
ModificadaCrítica (9.8)75%—Windriver VxworksNetapp E-series Santricity OS ControllerSonicwall SonicosSiemens Siprotec 5 Firmware+89/8/201917/6/2026
Wind River VxWorks has a Buffer Overflow in the TCP component (issue 1 of 4). This is a IPNET security vulnerability: TCP Urgent Pointer = 0 that leads to an integer underflow.
ModificadaMedia (5.3)60%—Windriver VxworksSonicwall SonicosSiemens Siprotec 5 FirmwareNetapp E-series Santricity OS Controller+89/8/201917/6/2026
Wind River VxWorks 6.5, 6.6, 6.7, 6.8, 6.9.3 and 6.9.4 has a Memory Leak in the IGMPv3 client component. There is an IPNET security vulnerability: IGMP Information leak via IGMPv3 specific membership report.
ModificadaAlta (8.1)3.2%—Windriver VxworksSonicwall SonicosSiemens Siprotec 5 FirmwareNetapp E-series Santricity OS Controller+89/8/201917/6/2026
Wind River VxWorks 6.9.4 and vx7 has a Buffer Overflow in the TCP component (issue 4 of 4). There is an IPNET security vulnerability: TCP Urgent Pointer state confusion due to race condition.
ModificadaAlta (7.5)16%—Windriver VxworksSonicwall SonicosSiemens Siprotec 5 FirmwareSiemens Ruggedcom Win7000 Firmware+79/8/201917/6/2026
Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and vx7 has an array index error in the IGMPv3 client component. There is an IPNET security vulnerability: DoS via NULL dereference in IGMP parsing.
ModificadaAlta (8.8)84%—Windriver VxworksSonicwall SonicosSiemens Siprotec 5 FirmwareNetapp E-series Santricity OS Controller+69/8/201917/6/2026
Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc.
ModificadaCrítica (9.8)27%—Windriver VxworksNetapp E-series Santricity OS ControllerSonicwall SonicosSiemens Siprotec 5 Firmware+89/8/201917/6/2026
Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets’ IP options.
ModificadaAlta (7.1)8.3%—Windriver VxworksBelden Hirschmann HiosBelden Garrettcom Magnum Dx940e FirmwareSiemens Ruggedcom Win7000 Firmware+35/8/201917/6/2026
Wind River VxWorks 6.6, 6.7, 6.8, 6.9.3, 6.9.4, and Vx7 has Incorrect Access Control in IPv4 assignment by the ipdhcpc DHCP client component.