Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2855▼ 166 respecto a la semana anterior
Críticas / altas1379▲ 45 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)266▼ 260 respecto a la semana anterior
17 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Aplazada | Media (6.5) | 0.19% | — | Beckhoff Twincat Package ManagerAI | 31/10/2024 | 17/6/2026 | A local user with administrative access rights can enter specialy crafted values for settings at the user interface (UI) of the TwinCAT Package Manager which then causes arbitrary OS commands to be executed. | |
| Modificada | Alta (7.3) | 0.27% | — | Beckhoff MDP PackageBeckhoff Twincat/bsd | 27/8/2024 | 17/6/2026 | The MPD package included in TwinCAT/BSD allows an authenticated, low-privileged local attacker to induce a Denial-of-Service (DoS) condition on the daemon and execute code in the context of user “root” via a crafted HTTP request. | |
| Analizada | Media (5.5) | 0.16% | — | Beckhoff IPC Diagnostics PackageBeckhoff Twincat/bsd | 27/8/2024 | 17/6/2026 | The IPC-Diagnostics package included in TwinCAT/BSD is vulnerable to a local denial-of-service attack by a low privileged attacker. | |
| Analizada | Alta (7.3) | 0.24% | — | Beckhoff IPC Diagnostics PackageBeckhoff Twincat/bsd | 27/8/2024 | 17/6/2026 | The IPC-Diagnostics package in TwinCAT/BSD is susceptible to improper input neutralization by a low-privileged local attacker. | |
| Analizada | Alta (7.8) | 0.16% | — | Beckhoff IPC Diagnostics PackageBeckhoff Twincat/bsd | 27/8/2024 | 17/6/2026 | The IPC-Diagnostics package included in TwinCAT/BSD is vulnerable to a local authentication bypass by a low privileged attacker. | |
| Modificada | Media (5.3) | 0.95% | — | Beckhoff IPC Diagnostics UA ServerBeckhoff Tf6100Beckhoff Twincat OPC UA Server | 13/5/2021 | 17/6/2026 | TwinCAT OPC UA Server in versions up to 2.3.0.12 and IPC Diagnostics UA Server in versions up to 3.1.0.1 from Beckhoff Automation GmbH & Co. KG are vulnerable to denial of service attacks. The attacker needs to send several specifically crafted requests to the running OPC UA server. After some of these requests the… | |
| Modificada | Alta (7.3) | 0.88% | — | Beckhoff Twincat Extended Automation Runtime | 19/11/2020 | 17/6/2026 | The default installation path of the TwinCAT XAR 3.1 software in all versions is underneath C:\TwinCAT. If the directory does not exist it and further subdirectories are created with permissions which allow every local user to modify the content. The default installation registers TcSysUI.exe for automatic execution… | |
| Modificada | Media (5.3) | 1.0% | — | Beckhoff Twincat DriverBeckhoff Twincat | 16/6/2020 | 17/6/2026 | Beckhoff's TwinCAT RT network driver for Intel 8254x and 8255x is providing EtherCAT functionality. The driver implements real-time features. Except for Ethernet frames sent from real-time functionality, all other Ethernet frames sent through the driver are not padded if their payload is less than the minimum Ethernet… | |
| Modificada | Crítica (9.8) | 5.3% | — | Beckhoff Twincat | 19/12/2019 | 17/6/2026 | Beckhoff Embedded Windows PLCs through 3.1.4024.0, and Beckhoff Twincat on Windows Engineering stations, allow an attacker to achieve Remote Code Execution (as SYSTEM) via the Beckhoff ADS protocol. | |
| Modificada | Alta (7.5) | 1.4% | — | Beckhoff Twincat | 21/11/2019 | 17/6/2026 | When Beckhoff TwinCAT is configured to use the Profinet driver, a denial of service of the controller could be reached by sending a malformed UDP packet to the device. This issue affects TwinCAT 2 version 2304 (and prior) and TwinCAT 3.1 version 4204.0 (and prior). | |
| Modificada | Alta (7.5) | 1.4% | — | Beckhoff Twincat | 21/11/2019 | 17/6/2026 | When a Beckhoff TwinCAT Runtime receives a malformed UDP packet, the ADS Discovery Service shuts down. Note that the TwinCAT devices are still performing as normal. This issue affects TwinCAT 2 version 2304 (and prior) and TwinCAT 3.1 version 4204.0 (and prior). | |
| Modificada | Crítica (9.1) | 0.51% | — | Beckhoff Twincat | 27/6/2018 | 17/6/2026 | Beckhoff TwinCAT supports communication over ADS. ADS is a protocol for industrial automation in protected environments. ADS has not been designed to achieve security purposes and therefore does not include any encryption algorithms because of their negative effect on performance and throughput. An attacker can forge… | |
| Modificada | Media (5.9) | 0.42% | — | Beckhoff Twincat | 27/6/2018 | 17/6/2026 | Beckhoff TwinCAT 3 supports communication over ADS. ADS is a protocol for industrial automation in protected environments. This protocol uses user configured routes, that can be edited remotely via ADS. This special command supports encrypted authentication with username/password. The encryption uses a fixed key, that… | |
| Modificada | Alta (7.8) | 0.56% | — | Beckhoff TwincatBeckhoff Twincat C++ | 23/3/2018 | 17/6/2026 | Kernel drivers in Beckhoff TwinCAT 3.1 Build 4022.4, TwinCAT 2.11 R3 2259, and TwinCAT 3.1 lack proper validation of user-supplied pointer values. An attacker who is able to execute code on the target may be able to exploit this vulnerability to obtain SYSTEM privileges. | |
| Modificada | Crítica (9.1) | 4.3% | — | Beckhoff Embedded PC ImagesBeckhoff Twincat | 5/10/2016 | 17/6/2026 | Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components might allow remote attackers to obtain access via the (1) Windows CE Remote Configuration Tool, (2) CE Remote Display service, or (3) TELNET service. | |
| Modificada | Crítica (9.1) | 4.8% | — | Beckhoff Embedded PC ImagesBeckhoff Twincat | 5/10/2016 | 17/6/2026 | Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components do not restrict the number of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack. | |
| Modificada | Media (5) | 50% | — | Beckhoff Twincat | 16/9/2011 | 16/6/2026 | Beckhoff TwinCAT 2.11.0.2004 and earlier allows remote attackers to cause a denial of service via a crafted request to UDP port 48899, which triggers an out-of-bounds read. |