Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2698▼ 345 respecto a la semana anterior
Críticas / altas1316▼ 9 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)244▼ 273 respecto a la semana anterior
–

5 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)1.7%—Siemens Sinumerik 840d SL FirmwareSiemens Simatic S7-300 CPU 312 FirmwareSiemens Simatic S7-300 CPU 314 FirmwareSiemens Simatic S7-300 CPU 315-2 DP Firmware+812/11/202017/6/2026
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC TDC CPU555 (All versions), SINUMERIK 840D sl (All versions). Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port 102. A cold…
ModificadaBaja (3.7)1.9%—Siemens Sinumerik 828d FirmwareSiemens Sinumerik 840d SL Firmware12/12/201817/6/2026
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a…
ModificadaAlta (8.7)3.3%—Siemens Simatic S7-200 FirmwareSiemens Simatic S7-400pn V6 FirmwareSiemens Simatic S7-400h V6 FirmwareSiemens Simatic S7-400pn/dp V7 Firmware+3426/12/201717/6/2026
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
ModificadaAlta (7.1)0.91%—Siemens Simatic CP 343-1 STD FirmwareSiemens Simatic CP 343-1 Lean FirmwareSiemens Simatic CP 343-1 ADV FirmwareSiemens Simatic CP 443-1 STD Firmware+7511/5/201717/6/2026
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
ModificadaAlta (7.1)1.1%—Siemens Simatic CP 343-1 STD FirmwareSiemens Simatic CP 343-1 Lean FirmwareSiemens Simatic CP 343-1 ADV FirmwareSiemens Simatic CP 443-1 STD Firmware+8911/5/201717/6/2026
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.