Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2720▼ 598 respecto a la semana anterior
Críticas / altas1299▼ 202 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)299▼ 211 respecto a la semana anterior
6 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (5.4) | 0.88% | — | Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+8 | 14/5/2019 | 17/6/2026 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime… | |
| Modificada | Media (6.5) | 1.7% | — | Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+8 | 14/5/2019 | 17/6/2026 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime… | |
| Modificada | Crítica (9.1) | 2.7% | — | Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+8 | 14/5/2019 | 17/6/2026 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime… | |
| Modificada | Alta (8.8) | 1.7% | — | Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+8 | 13/12/2018 | 17/6/2026 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14),… | |
| Modificada | Alta (8.1) | 1.7% | — | Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+8 | 13/12/2018 | 17/6/2026 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced… | |
| Modificada | Alta (7.5) | 3.6% | — | Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+8 | 13/12/2018 | 17/6/2026 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced… |