| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Analizada | Crítica (9.6) | 1.1% | ⚠ Explotación activa | Tanstack/arktype-adapterTanstack/eslint-plugin-routerTanstack/eslint-plugin-startTanstack/history+167 | 12/5/2026 | 17/6/2026 | On 2026-05-11, between approximately 19:20 and 19:26 UTC, 84 malicious versions across 42 @tanstack/* packages were published to the npm registry. The publishes were authenticated via the legitimate GitHub Actions OIDC trusted-publisher binding for TanStack/router, but the publish workflow itself was not modified. The… | |
| Aplazada | Crítica (10) | 0.69% | — | Ventilator Manufacturer Ventilator Service ToolsAI | 14/11/2024 | 17/6/2026 | The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the… | |
| Modificada | Crítica (9.8) | 1.9% | — | Hillrom Connex Central StationHillrom Connex Device Integration Suite Network Connectivity EngineHillrom Connex Integrated Wall SystemHillrom Connex Spot Monitor+5 | 11/6/2021 | 17/6/2026 | The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior… | |
| Modificada | Alta (7.5) | 1.7% | — | Hillrom Connex Central StationHillrom Connex Device Integration Suite Network Connectivity EngineHillrom Connex Integrated Wall SystemHillrom Connex Spot Monitor+5 | 11/6/2021 | 17/6/2026 | The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device… | |
| Modificada | Media (5) | 1.9% | — | HP Webes Service Tools | 4/10/2002 | 16/6/2026 | Unknown vulnerability in Compaq WEBES Service Tools 2.0 through WEBES 4.0 (Service Pack 5) allows local users to read privileged files. |