Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2997▼ 66 respecto a la semana anterior
Críticas / altas1460▲ 109 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)339▼ 171 respecto a la semana anterior
8 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (5.1) | 0.72% | — | Siemens Ruggedcom Rm1224 Lte(4g) EU FirmwareSiemens Ruggedcom Rm1224 Lte(4g) NAM FirmwareSiemens Scalance M804pb FirmwareSiemens Scalance M812-1 Adsl-router Firmware+97 | 13/12/2022 | 17/6/2026 | Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. | |
| Modificada | Media (5.2) | 0.27% | — | Siemens Ruggedcom Rm1224 Lte(4g) EU FirmwareSiemens Ruggedcom Rm1224 Lte(4g) NAM FirmwareSiemens Scalance M804pb FirmwareSiemens Scalance M812-1 Adsl-router Firmware+97 | 13/12/2022 | 17/6/2026 | Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. | |
| Modificada | Alta (7.1) | 0.24% | — | Siemens Ruggedcom Rm1224 Lte(4g) EU FirmwareSiemens Ruggedcom Rm1224 Lte(4g) NAM FirmwareSiemens Scalance M804pb FirmwareSiemens Scalance M812-1 Adsl-router Firmware+97 | 13/12/2022 | 17/6/2026 | Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system. | |
| Modificada | Media (4.8) | 0.96% | — | Siemens Scalance M-800 FirmwareSiemens Scalance S615 FirmwareSiemens Scalance Sc-600 FirmwareSiemens Scalance Sc622-2c Firmware+86 | 10/8/2022 | 17/6/2026 | Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. | |
| Modificada | Alta (7.5) | 1.7% | — | Siemens Scalance M-800 FirmwareSiemens Scalance S615 FirmwareSiemens Scalance W700 Ieee 802.11ax FirmwareSiemens Scalance W700 Ieee 802.11n Firmware+80 | 10/8/2022 | 17/6/2026 | Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. | |
| Modificada | Alta (7.2) | 1.8% | — | Siemens Scalance M-800 FirmwareSiemens Scalance S615 FirmwareSiemens Scalance Sc-600 FirmwareSiemens Scalance Sc622-2c Firmware+86 | 10/8/2022 | 17/6/2026 | Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. | |
| Modificada | Alta (7.5) | 0.62% | — | Siemens Scalance Xm408-4c FirmwareSiemens Scalance Xm408-4c L3 FirmwareSiemens Scalance Xm408-8c FirmwareSiemens Scalance Xm408-8c L3 Firmware+13 | 14/6/2022 | 17/6/2026 | A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5),… | |
| Modificada | Alta (7.5) | 1.6% | — | Siemens Scalance Xm-400 FirmwareSiemens Scalance Xr524 FirmwareSiemens Scalance Xr526 FirmwareSiemens Scalance Xr528 Firmware+7 | 12/5/2021 | 17/6/2026 | An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4). |