Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2970▼ 106 respecto a la semana anterior
Críticas / altas1447▲ 86 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)350▼ 160 respecto a la semana anterior
–

7 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaMedia (5.9)64%💥 PoCOpensslDebian LinuxFreebsdNetapp Active IQ Unified Manager+10225/3/202117/6/2026
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer…
ModificadaMedia (6.1)0.74%—Siemens Scalance S602 FirmwareSiemens Scalance S612 FirmwareSiemens Scalance S623 FirmwareSiemens Scalance S627-2m Firmware10/3/202017/6/2026
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow…
ModificadaAlta (7.5)1.5%—Siemens Scalance S602 FirmwareSiemens Scalance S612 FirmwareSiemens Scalance S623 FirmwareSiemens Scalance S627-2m Firmware11/2/202017/6/2026
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a…
ModificadaAlta (7.5)1.5%—Siemens Scalance S602 FirmwareSiemens Scalance S612 FirmwareSiemens Scalance S623 FirmwareSiemens Scalance S627-2m Firmware11/2/202017/6/2026
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a…
ModificadaMedia (5.4)0.69%—Siemens Scalance S602 FirmwareSiemens Scalance S612 FirmwareSiemens Scalance S623 FirmwareSiemens Scalance S627-2m Firmware13/12/201817/6/2026
A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into…
ModificadaMedia (6.1)1.6%—Siemens Scalance S FirmwareSiemens Scalance S602Siemens Scalance S612Siemens Scalance S61318/4/201216/6/2026
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.
ModificadaAlta (10)5.0%—Siemens Scalance S FirmwareSiemens Scalance S602Siemens Scalance S612Siemens Scalance S61318/4/201216/6/2026
The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the administrative password.
Orbitaley — Vulnerabilidades