ModificadaMedia (6.5)0.10%—Emerson Openenterprise Scada Server19/5/202217/6/2026
Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and external systems to be obtained.
ModificadaCrítica (9.8)1.1%—Smartptt Scada Server29/4/202217/6/2026
Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization.
ModificadaAlta (8.8)0.37%—Smartptt Scada Server29/4/202217/6/2026
Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
ModificadaAlta (7.5)1.1%—Fernhillsoftware Scada Server12/4/202217/6/2026
A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process (FHSvrService.exe) to exit.
ModificadaCrítica (9.8)3.1%—Emerson Openenterprise Scada Server24/2/202217/6/2026
Emerson OpenEnterprise versions through 3.3.4 may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service.
ModificadaAlta (7.5)0.28%—Emerson Openenterprise Scada Server24/2/202217/6/2026
Inadequate encryption may allow the passwords for Emerson OpenEnterprise versions through 3.3.4 user accounts to be obtained.
ModificadaMedia (5.3)0.47%—Emerson Openenterprise Scada Server24/2/202217/6/2026
Inadequate folder security permissions in Emerson OpenEnterprise versions through 3.3.4 may allow modification of important configuration files, which could cause the system to fail or behave in an unpredictable manner.
ModificadaCrítica (9.8)2.6%—Emerson Openenterprise Scada Server19/2/202017/6/2026
A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server.