| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (8.8) | 1.5% | — | Teltonika-networks Rut200 FirmwareTeltonika-networks Rut240 FirmwareTeltonika-networks Rut241 FirmwareTeltonika-networks Rut300 Firmware+14 | 22/5/2023 | 17/6/2026 | Versions 00.07.00 through 00.07.03 of Teltonika’s RUT router firmware contain an operating system (OS) command injection vulnerability in a Lua service. An attacker could exploit a parameter in the vulnerable function that calls a user-provided package name by instead providing a package with a malicious name that… | |
| Modificada | Alta (8.8) | 1.1% | — | Teltonika-networks Rut200 FirmwareTeltonika-networks Rut240 FirmwareTeltonika-networks Rut241 FirmwareTeltonika-networks Rut300 Firmware+14 | 22/5/2023 | 17/6/2026 | Version 00.07.03.4 and prior of Teltonika’s RUT router firmware contain a packet dump utility that contains proper validation for filter parameters. However, variables for validation checks are stored in an external configuration file. An authenticated attacker could use an exposed UCI configuration utility to change… | |
| Modificada | Media (6.5) | 1.2% | — | Teltonika Rut950 Firmware | 19/6/2019 | 17/6/2026 | An issue was discovered on Teltonika RTU950 R_31.04.89 devices. The application allows a user to login without limitation. For every successful login request, the application saves a session. A user can re-login without logging out, causing the application to store the session in memory. Exploitation of this… | |
| Modificada | Crítica (9.8) | 1.3% | — | Teltonika Rut950 Firmware | 28/3/2019 | 17/6/2026 | An issue was discovered in /cgi-bin/luci on Teltonika RTU9XX (e.g., RUT950) R_31.04.89 before R_00.05.00.5 devices. The authentication functionality is not protected from automated tools used to make login attempts to the application. An anonymous attacker has the ability to make unlimited login attempts with an… | |
| Modificada | Media (6.8) | 0.72% | — | Teltonika Rut900 FirmwareTeltonika Rut950 FirmwareTeltonika Rut955 Firmware | 15/10/2018 | 17/6/2026 | Teltonika RUT9XX routers with firmware before 00.04.233 provide a root terminal on a serial interface without proper access control. This allows attackers with physical access to execute arbitrary commands with root privileges. | |
| Modificada | Media (6.1) | 2.0% | — | Teltonika Rut900 FirmwareTeltonika Rut950 FirmwareTeltonika Rut955 Firmware | 15/10/2018 | 17/6/2026 | Teltonika RUT9XX routers with firmware before 00.05.01.1 are prone to cross-site scripting vulnerabilities in hotspotlogin.cgi due to insufficient user input sanitization. | |
| Modificada | Crítica (9.8) | 71% | — | Teltonika Rut900 FirmwareTeltonika Rut950 FirmwareTeltonika Rut955 Firmware | 15/10/2018 | 17/6/2026 | Teltonika RUT9XX routers with firmware before 00.04.233 are prone to multiple unauthenticated OS command injection vulnerabilities in autologin.cgi and hotspotlogin.cgi due to insufficient user input sanitization. This allows remote attackers to execute arbitrary commands with root privileges. | |
| Modificada | Crítica (9.8) | 4.5% | — | Teltonika Rut900 FirmwareTeltonika Rut905 FirmwareTeltonika Rut950 FirmwareTeltonika Rut955 Firmware | 3/7/2017 | 17/6/2026 | The management interface for the Teltonika RUT9XX routers (aka LuCI) with firmware 00.03.265 and earlier allows remote attackers to execute arbitrary commands with root privileges via shell metacharacters in the username parameter in a login request. |