Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2661▼ 437 respecto a la semana anterior
Críticas / altas1284▼ 85 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)247▼ 271 respecto a la semana anterior
–

8 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (8.8)1.5%—Teltonika-networks Rut200 FirmwareTeltonika-networks Rut240 FirmwareTeltonika-networks Rut241 FirmwareTeltonika-networks Rut300 Firmware+1422/5/202317/6/2026
Versions 00.07.00 through 00.07.03 of Teltonika’s RUT router firmware contain an operating system (OS) command injection vulnerability in a Lua service. An attacker could exploit a parameter in the vulnerable function that calls a user-provided package name by instead providing a package with a malicious name that…
ModificadaAlta (8.8)1.1%—Teltonika-networks Rut200 FirmwareTeltonika-networks Rut240 FirmwareTeltonika-networks Rut241 FirmwareTeltonika-networks Rut300 Firmware+1422/5/202317/6/2026
Version 00.07.03.4 and prior of Teltonika’s RUT router firmware contain a packet dump utility that contains proper validation for filter parameters. However, variables for validation checks are stored in an external configuration file. An authenticated attacker could use an exposed UCI configuration utility to change…
ModificadaMedia (6.5)1.2%—Teltonika Rut950 Firmware19/6/201917/6/2026
An issue was discovered on Teltonika RTU950 R_31.04.89 devices. The application allows a user to login without limitation. For every successful login request, the application saves a session. A user can re-login without logging out, causing the application to store the session in memory. Exploitation of this…
ModificadaCrítica (9.8)1.3%—Teltonika Rut950 Firmware28/3/201917/6/2026
An issue was discovered in /cgi-bin/luci on Teltonika RTU9XX (e.g., RUT950) R_31.04.89 before R_00.05.00.5 devices. The authentication functionality is not protected from automated tools used to make login attempts to the application. An anonymous attacker has the ability to make unlimited login attempts with an…
ModificadaMedia (6.8)0.72%—Teltonika Rut900 FirmwareTeltonika Rut950 FirmwareTeltonika Rut955 Firmware15/10/201817/6/2026
Teltonika RUT9XX routers with firmware before 00.04.233 provide a root terminal on a serial interface without proper access control. This allows attackers with physical access to execute arbitrary commands with root privileges.
ModificadaMedia (6.1)2.0%—Teltonika Rut900 FirmwareTeltonika Rut950 FirmwareTeltonika Rut955 Firmware15/10/201817/6/2026
Teltonika RUT9XX routers with firmware before 00.05.01.1 are prone to cross-site scripting vulnerabilities in hotspotlogin.cgi due to insufficient user input sanitization.
ModificadaCrítica (9.8)71%—Teltonika Rut900 FirmwareTeltonika Rut950 FirmwareTeltonika Rut955 Firmware15/10/201817/6/2026
Teltonika RUT9XX routers with firmware before 00.04.233 are prone to multiple unauthenticated OS command injection vulnerabilities in autologin.cgi and hotspotlogin.cgi due to insufficient user input sanitization. This allows remote attackers to execute arbitrary commands with root privileges.
ModificadaCrítica (9.8)4.5%—Teltonika Rut900 FirmwareTeltonika Rut905 FirmwareTeltonika Rut950 FirmwareTeltonika Rut955 Firmware3/7/201717/6/2026
The management interface for the Teltonika RUT9XX routers (aka LuCI) with firmware 00.03.265 and earlier allows remote attackers to execute arbitrary commands with root privileges via shell metacharacters in the username parameter in a login request.