Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2987▼ 96 respecto a la semana anterior
Críticas / altas1458▲ 101 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)350▼ 160 respecto a la semana anterior
5 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 1.1% | — | Auto-maskin RP 210e FirmwareAuto-maskin DCU 210e FirmwareAuto-maskin Marine PRO Observer | 23/3/2020 | 17/6/2026 | In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak. | |
| Modificada | Alta (8.8) | 0.88% | — | Auto-maskin RP 210e FirmwareAuto-maskin DCU 210e FirmwareAuto-maskin Marine PRO Observer | 8/10/2018 | 17/6/2026 | The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App use an embedded webserver that uses unencrypted plaintext for the transmission of the administrator PIN Impact: An attacker once authenticated can change configurations, upload new configuration files, and upload executable code via file upload for… | |
| Modificada | Media (5.9) | 0.87% | — | Auto-maskin RP 210e FirmwareAuto-maskin DCU 210e FirmwareAuto-maskin Marine PRO Observer | 8/10/2018 | 17/6/2026 | The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App transmit sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The devices transmit process control information via unencrypted Modbus communications. Impact: An attacker can exploit… | |
| Modificada | Crítica (9.1) | 0.74% | — | Auto-maskin RP 210e FirmwareAuto-maskin DCU 210e Firmware | 8/10/2018 | 17/6/2026 | The Auto-Maskin products utilize an undocumented custom protocol to set up Modbus communications with other devices without validating those devices. The originating device sends a message in plaintext, 48:65:6c:6c:6f:20:57:6f:72:6c:64, "Hello World" over UDP ports 44444-44446 to the broadcast address for the LAN.… | |
| Modificada | Crítica (9.8) | 2.1% | — | Auto-maskin Dcu-210e FirmwareAuto-maskin Rp-210e Firmware | 8/10/2018 | 17/6/2026 | The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not… |