Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas3001▼ 62 respecto a la semana anterior
Críticas / altas1373▲ 34 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)459▼ 50 respecto a la semana anterior
5 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Aplazada | Media (6.3) | 0.30% | — | ABB Rmc-100AIABB Rmc-100 LiteAI | 3/7/2025 | 17/6/2026 | Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to source code and control network, the attacker can bypass the REST interface authentication and gain access to MQTT configuration data. This issue affects… | |
| Aplazada | Alta (8.2) | 0.42% | — | ABB Rmc-100AIABB Rmc-100 LiteAI | 3/7/2025 | 17/6/2026 | Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and user/password broker authentication is enabled, and CVE-2025-6074 is exploited, the attacker can overflow the buffer for username or… | |
| Aplazada | Alta (8.2) | 0.40% | — | ABB Rmc-100AIABB Rmc-100 LiteAI | 3/7/2025 | 17/6/2026 | Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.This issue affects… | |
| Aplazada | Media (6.3) | 0.28% | — | ABB Rmc-100AIABB Rmc-100 LiteAI | 3/7/2025 | 17/6/2026 | Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE. An attacker can gain access to salted information to decrypt MQTT information. This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016. | |
| Modificada | Crítica (9.8) | 16% | — | ABB Rmc-100 FirmwareABB Rmc-100-lite FirmwareABB XIO FirmwareABB Xfcg5 Firmware+3 | 21/7/2022 | 17/6/2026 | Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an… |