Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2622▼ 226 respecto a la semana anterior
Críticas / altas1383▲ 155 respecto a la semana anterior
Nueva explotación activa (KEV)7▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)56▼ 472 respecto a la semana anterior
5 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 0.56% | — | Dallmann-consulting Open Charge Point Protocol | 7/12/2023 | 17/6/2026 | An issue was discovered in Dalmann OCPP.Core through 1.2.0 for OCPP (Open Charge Point Protocol) for electric vehicles. The server processes mishandle StartTransaction messages containing additional, arbitrary properties, or duplicate properties. The last occurrence of a duplicate property is accepted. This could be… | |
| Modificada | Alta (7.5) | 0.53% | — | Dallmann-consulting Open Charge Point Protocol | 7/12/2023 | 17/6/2026 | An issue was discovered in Dalmann OCPP.Core before 1.3.0 for OCPP (Open Charge Point Protocol) for electric vehicles. It permits multiple transactions with the same connectorId and idTag, contrary to the expected ConcurrentTx status. This could result in critical transaction management and billing errors. NOTE: the… | |
| Modificada | Alta (7.5) | 0.71% | — | Dallmann-consulting Open Charge Point Protocol | 7/12/2023 | 17/6/2026 | An issue was discovered in Dalmann OCPP.Core before 1.3.0 for OCPP (Open Charge Point Protocol) for electric vehicles. A StopTransaction message with any random transactionId terminates active transactions. | |
| Modificada | Alta (7.5) | 0.71% | — | Dallmann-consulting Open Charge Point Protocol | 7/12/2023 | 17/6/2026 | An issue was discovered in Dalmann OCPP.Core before 1.2.0 for OCPP (Open Charge Point Protocol) for electric vehicles. It does not validate the length of the chargePointVendor field in a BootNotification message, potentially leading to server instability and a denial of service when processing excessively large… | |
| Modificada | Crítica (9.8) | 2.2% | — | Circontrol Open Charge Point Protocol | 18/9/2018 | 17/6/2026 | An issue was discovered in CIRCONTROL Open Charge Point Protocol (OCPP) before 1.5.0, as used in CirCarLife, PowerStudio, and other products. Due to storage of credentials in XML files, an unprivileged user can look at /services/config/config.xml for the admin credentials of the ocpp and circarlife panels. |