Resumen — últimos 7 días
Vulnerabilidades nuevas2698▼ 345 respecto a la semana anterior
Críticas / altas1316▼ 9 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)244▼ 273 respecto a la semana anterior
9 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Crítica (9.1) | 2.2% | — | Siemens Capital VstarSiemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Readystart V4+7 | 9/11/2021 | 17/6/2026 | A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload… | |
| Modificada | Alta (7.5) | 1.2% | — | Siemens Capital VstarSiemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Readystart V4+7 | 9/11/2021 | 17/6/2026 | A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions <… | |
| Modificada | Crítica (9.1) | 2.0% | — | Siemens Capital VstarSiemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Readystart V4+7 | 9/11/2021 | 17/6/2026 | A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload… | |
| Modificada | Media (6.9) | 1.5% | — | Siemens Capital VstarSiemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Readystart V4+7 | 9/11/2021 | 17/6/2026 | A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP… | |
| Modificada | Media (5.3) | 1.1% | — | Siemens Simotics Connect 400 FirmwareSiemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Readystart V4+1 | 22/4/2021 | 17/6/2026 | A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All… | |
| Modificada | Alta (8.7) | 1.9% | — | Siemens Capital VstarSiemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Readystart V4+1 | 22/4/2021 | 17/6/2026 | A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including… | |
| Modificada | Alta (7.4) | 3.7% | — | Siemens Simotics Connect 400 FirmwareSiemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Readystart V4+1 | 22/4/2021 | 17/6/2026 | A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All… | |
| Modificada | Media (6.5) | 3.6% | — | Siemens Simotics Connect 400 FirmwareSiemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Readystart V4+1 | 22/4/2021 | 17/6/2026 | A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All… | |
| Modificada | Media (6.5) | 3.6% | — | Siemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Readystart V4Siemens Nucleus Source Code+1 | 22/4/2021 | 17/6/2026 | A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All… |