Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2619▼ 461 respecto a la semana anterior
Críticas / altas1277▼ 72 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)235▼ 274 respecto a la semana anterior
–

13 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaMedia (4.6)0.26%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow an attacker to gain access the the BIOS menu because is has no password.
ModificadaCrítica (9.1)0.46%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and…
ModificadaMedia (6.8)0.33%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate Attacker to Escalate Privileges by enabling the USB interface through chassis probe insertion during system boot, aka "Unauthorized Reactivation of the USB…
ModificadaAlta (7.2)0.31%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components.
ModificadaMedia (4.1)0.19%—Entrust Nshield Connect XC High FirmwareEntrust Nshield Connect XC MID FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Hsmi Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a physically proximate attacker (with elevated privileges) to read and modify the Appliance SSD contents (because they are unencrypted).
ModificadaBaja (3.9)0.18%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a physically proximate attacker with root access to modify the Recovery Partition (because of a lack of integrity protection).
ModificadaMedia (6.8)0.33%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a physically proximate attacker to escalate privileges by booting from a USB device with a valid root filesystem. This occurs because of insecure default settings in the Legacy GRUB…
ModificadaMedia (6.8)0.33%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), might allow a physically proximate attacker to gain access to the EOL legacy bootloader.
ModificadaAlta (7.2)0.31%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a physically proximate attacker to escalate privileges by editing the Legacy GRUB bootloader configuration to start a root shell upon boot of the host OS. This is called F06.
ModificadaBaja (3.2)0.24%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a physically proximate attacker to modify or erase tamper events via the Chassis management board.
ModificadaCrítica (9.8)0.67%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a user with OS root access to alter firmware on the Chassis Management Board (without Authentication). This is called F04.
ModificadaMedia (6.8)0.32%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allows a physically proximate attacker to persistently modify firmware and influence the (insecurely configured) appliance boot process. To exploit this, the…
ModificadaCrítica (9.8)0.90%—Entrust Nshield 5C FirmwareEntrust Nshield Hsmi FirmwareEntrust Nshield Connect XC Base FirmwareEntrust Nshield Connect XC MID Firmware+12/12/202526/8/2026
The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allows a physically proximate attacker to obtain debug access and escalate privileges by bypassing the tamper label and opening the chassis without leaving…