ModificadaAlta (8)0.77%—Schneider-electric Rack Power Distribution Unit With Network Management Card 2 FirmwareSchneider-electric Rack Power Distribution Unit With Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or…
ModificadaMedia (5.3)0.77%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J,…
ModificadaMedia (6.1)0.74%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and…
ModificadaMedia (6.1)0.74%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase…
ModificadaMedia (6.1)0.74%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2…
ModificadaMedia (6.1)0.74%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2…
ModificadaMedia (6.1)0.75%—Schneider-electric Network Management Card 2 FirmwareSchneider-electric Network Management Card 3 Firmware28/1/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase…