Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2698▼ 345 respecto a la semana anterior
Críticas / altas1316▼ 9 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)244▼ 273 respecto a la semana anterior
6 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Crítica (9.8) | 1.2% | — | GE Multilin B30 FirmwareGE Multilin B90 FirmwareGE Multilin C60 FirmwareGE Multilin C70 Firmware+15 | 23/3/2022 | 17/6/2026 | GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The… | |
| Modificada | Crítica (9.8) | 1.2% | — | GE Multilin B30 FirmwareGE Multilin B90 FirmwareGE Multilin C60 FirmwareGE Multilin C70 Firmware+15 | 23/3/2022 | 17/6/2026 | GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factory” user. | |
| Modificada | Media (5.3) | 0.88% | — | GE Multilin B30 FirmwareGE Multilin B90 FirmwareGE Multilin C60 FirmwareGE Multilin C70 Firmware+15 | 23/3/2022 | 17/6/2026 | GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a “Last-key pressed” MODBUS register can be used to gain unauthorized information. | |
| Modificada | Alta (7.5) | 0.67% | — | GE Multilin B30 FirmwareGE Multilin B90 FirmwareGE Multilin C60 FirmwareGE Multilin C70 Firmware+15 | 23/3/2022 | 17/6/2026 | GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication. | |
| Modificada | Media (5.3) | 1.1% | — | GE Multilin B30 FirmwareGE Multilin B90 FirmwareGE Multilin C60 FirmwareGE Multilin C70 Firmware+15 | 23/3/2022 | 17/6/2026 | GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not… | |
| Modificada | Media (6.1) | 0.61% | — | GE Multilin B30 FirmwareGE Multilin B90 FirmwareGE Multilin C60 FirmwareGE Multilin C70 Firmware+15 | 23/3/2022 | 17/6/2026 | GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of… |