Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2817▼ 183 respecto a la semana anterior
Críticas / altas1372▲ 48 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)247▼ 271 respecto a la semana anterior
9 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Crítica (9.8) | 2.1% | — | Mitsubishielectric EzsocketMitsubishielectric FR Configurator2Mitsubishielectric Got1000Mitsubishielectric Got2000+6 | 30/1/2024 | 17/6/2026 | Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX… | |
| Modificada | Alta (7.5) | 0.95% | — | Mitsubishielectric EzsocketMitsubishielectric FR Configurator2Mitsubishielectric Got1000Mitsubishielectric Got2000+6 | 30/1/2024 | 17/6/2026 | Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior,… | |
| Modificada | Crítica (9.8) | 0.85% | — | Mitsubishielectric CPU Module Logging Configuration ToolMitsubishielectric CW ConfiguratorMitsubishielectric Data TransferMitsubishielectric EM Configurator+25 | 19/5/2022 | 17/6/2026 | Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed,… | |
| Modificada | Crítica (9.8) | 2.3% | — | Mitsubishielectric CW ConfiguratorMitsubishielectric FR Configurator2Mitsubishielectric GX Works2Mitsubishielectric GX Works3+16 | 11/2/2022 | 17/6/2026 | Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code. | |
| Modificada | Crítica (9.8) | 1.3% | — | Mitsubishielectric C Controller Interface Module UtilityMitsubishielectric C Controller Module Setting AND Monitoring ToolMitsubishielectric Cc-link IE Control Network Data CollectorMitsubishielectric Cc-link IE Field Network Data Collector+42 | 11/2/2022 | 17/6/2026 | Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. | |
| Modificada | Crítica (9.8) | 6.9% | — | Mitsubishielectric C Controller Module Setting AND Monitoring ToolMitsubishielectric CPU Module Logging Configuration ToolMitsubishielectric CW ConfiguratorMitsubishielectric Data Transfer+37 | 19/2/2021 | 17/6/2026 | Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all… | |
| Modificada | Crítica (9.8) | 3.9% | — | Mitsubishielectric C Controller Module Setting AND Monitoring ToolMitsubishielectric CPU Module Logging Configuration ToolMitsubishielectric CW ConfiguratorMitsubishielectric Data Transfer+37 | 19/2/2021 | 17/6/2026 | Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3… | |
| Modificada | Alta (7.5) | 1.3% | — | Mitsubishielectric CPU Module Logging Configuration ToolMitsubishielectric CW ConfiguratorMitsubishielectric EM ConfiguratorMitsubishielectric GT Designer3+16 | 30/6/2020 | 17/6/2026 | Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier,… | |
| Modificada | Alta (7.5) | 1.4% | — | Mitsubishielectric CPU Module Logging Configuration ToolMitsubishielectric CW ConfiguratorMitsubishielectric EM ConfiguratorMitsubishielectric GT Designer3+16 | 30/6/2020 | 17/6/2026 | Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver.… |