Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2997▼ 66 respecto a la semana anterior
Críticas / altas1460▲ 109 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)339▼ 171 respecto a la semana anterior
16 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Analizada | Alta (8.1) | 0.32% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp341000h FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 Firmware+42 | 14/2/2024 | 17/6/2026 | CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack. | |
| Modificada | Media (5.3) | 1.1% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+15 | 11/12/2020 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause denial of HTTP and FTP services when a… | |
| Modificada | Alta (7.5) | 1.3% | — | Schneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep582040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Modicon M580 Bmep585040 Firmware+12 | 11/12/2020 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over… | |
| Modificada | Alta (7.5) | 1.3% | — | Schneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep582040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Modicon M580 Bmep585040 Firmware+16 | 11/12/2020 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over… | |
| Modificada | Media (5.3) | 0.91% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+16 | 11/12/2020 | 17/6/2026 | A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted… | |
| Modificada | Crítica (9.8) | 2.3% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+19 | 11/12/2020 | 17/6/2026 | A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller… | |
| Modificada | Alta (7.5) | 1.2% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+16 | 11/12/2020 | 17/6/2026 | A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a… | |
| Modificada | Alta (7.5) | 1.4% | — | Schneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep582040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Modicon M580 Bmep585040 Firmware+15 | 11/12/2020 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over… | |
| Modificada | Alta (7.5) | 1.2% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+6 | 11/12/2020 | 17/6/2026 | A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to… | |
| Modificada | Alta (7.5) | 1.5% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+17 | 11/12/2020 | 17/6/2026 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause… | |
| Modificada | Alta (7.5) | 1.3% | — | Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+53 | 18/4/2018 | 17/6/2026 | A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. | |
| Modificada | Crítica (9.8) | 2.1% | — | Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+53 | 18/4/2018 | 17/6/2026 | A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution. | |
| Modificada | Crítica (9.8) | 1.5% | — | Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+53 | 18/4/2018 | 17/6/2026 | An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization. | |
| Modificada | Alta (7.5) | 1.3% | — | Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+53 | 18/4/2018 | 17/6/2026 | A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied. | |
| Modificada | Crítica (9.8) | 1.9% | — | Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+53 | 18/4/2018 | 17/6/2026 | Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks. | |
| Modificada | Crítica (9.8) | 3.7% | — | Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+53 | 18/4/2018 | 17/6/2026 | Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. |