Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2970▼ 106 respecto a la semana anterior
Críticas / altas1447▲ 86 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)350▼ 160 respecto a la semana anterior
9 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Analizada | Alta (8.1) | 0.32% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp341000h FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 Firmware+42 | 14/2/2024 | 17/6/2026 | CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack. | |
| Modificada | Alta (7.5) | 0.63% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 FirmwareSchneider-electric Modicon M340 Bmxp3420102 Firmware+37 | 1/2/2023 | 17/6/2026 | A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP*… | |
| Modificada | Crítica (9.8) | 1.5% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+33 | 31/1/2023 | 17/6/2026 | A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU… | |
| Modificada | Crítica (9.8) | 1.2% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+51 | 30/1/2023 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions),… | |
| Modificada | Alta (7.5) | 0.61% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 FirmwareSchneider-electric Modicon M340 Bmxp3420102 Firmware+10 | 22/11/2022 | 17/6/2026 | A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100… | |
| Modificada | Crítica (9.8) | 0.77% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+32 | 12/9/2022 | 17/6/2026 | A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control… | |
| Modificada | Alta (7.5) | 0.93% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 FirmwareSchneider-electric Modicon M340 Bmxp3420102 Firmware+2 | 4/2/2022 | 17/6/2026 | A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 (HTTP) and 502 (Modbus), when sending a large number of TCP RST or FIN packets to any open TCP port of the PLC. Affected Product: Modicon M340 CPUs: BMXP34 (All Versions) | |
| Modificada | Crítica (9.1) | 1.0% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric RemoteconnectSchneider-electric Modicon M580 Bmep581020 Firmware+28 | 14/7/2021 | 17/6/2026 | Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70… | |
| Modificada | Media (5) | 2.1% | — | Schneider-electric Modicon M340 BMX NOC 0401 FirmwareSchneider-electric Modicon M340 BMX NOE 0100 FirmwareSchneider-electric Modicon M340 BMX NOE 0100h FirmwareSchneider-electric Modicon M340 BMX NOE 0110 Firmware+8 | 4/4/2013 | 16/6/2026 | The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control… |