Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2980▼ 83 respecto a la semana anterior
Críticas / altas1452▲ 101 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)353▼ 157 respecto a la semana anterior
8 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.3) | 1.1% | — | Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump | 15/2/2018 | 17/6/2026 | A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to… | |
| Modificada | Media (5.6) | 0.83% | — | Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump | 15/2/2018 | 17/6/2026 | A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network… | |
| Modificada | Alta (8.1) | 1.3% | — | Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump | 15/2/2018 | 17/6/2026 | A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP… | |
| Modificada | Baja (3.7) | 0.97% | — | Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump | 15/2/2018 | 17/6/2026 | A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications. | |
| Modificada | Media (5.3) | 2.4% | — | Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump | 15/2/2018 | 17/6/2026 | An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module… | |
| Modificada | Media (5.9) | 0.67% | — | Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump | 15/2/2018 | 17/6/2026 | An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack. | |
| Modificada | Alta (8.1) | 1.9% | — | Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump | 15/2/2018 | 17/6/2026 | An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. | |
| Modificada | Alta (8.1) | 13% | 💥 Exploit | Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump | 15/2/2018 | 17/6/2026 | A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The… |