Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2797▼ 203 respecto a la semana anterior
Críticas / altas1352▲ 28 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)255▼ 266 respecto a la semana anterior
–

5 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
AplazadaCrítica (9.3)3.1%—Skybridge Basic Mb-a130AI1/9/202517/6/2026
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge BASIC MB-A130 Ver.1.5.8 and earlier. If exploited, a remote unauthenticated attacker may execute arbitrary OS commands with root privileges.
AplazadaCrítica (9.8)1.2%—Skybridge Mb-a100AISkybridge Mb-a110AISkybridge Mb-a130AI31/5/202417/6/2026
Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the…
ModificadaAlta (7.5)1.00%—Seiko-sol Skybridge Basic Mb-a130 FirmwareSeiko-sol Skybridge Mb-a200 FirmwareSeiko-sol Skyspider Mb-r210 Firmware10/5/202317/6/2026
Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware…
ModificadaMedia (6.5)0.46%—Seiko-sol Skybridge Basic Mb-a130 FirmwareSeiko-sol Skybridge Mb-a200 Firmware10/5/202317/6/2026
Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.
ModificadaAlta (8.6)0.98%—Seiko-sol Skybridge Basic Mb-a130 FirmwareSeiko-sol Skybridge Mb-a200 Firmware10/5/202317/6/2026
Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows:…