Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2561▼ 314 respecto a la semana anterior
Críticas / altas1347▲ 83 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 7 respecto a la semana anterior
Sin puntuar (sin CVSS)62▼ 466 respecto a la semana anterior
–

34 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
AnalizadaAlta (8.4)0.23%—Intouchapp Intouch Contacts & Caller ID31/3/202624/7/2026
An arbitrary file overwrite vulnerability in InTouch Contacts & Caller ID APP v6.38.1 allows attackers to overwrite critical internal files via the file import process, leading to arbitrary code execution or information exposure.
ModificadaAlta (7.1)0.22%—Aveva Batch ManagementAveva Communication DriversAveva EdgeAveva Enterprise Licensing+915/11/202317/6/2026
This external control vulnerability, if exploited, could allow a local OS-authenticated user with standard privileges to delete files with System privilege on the machine where these products are installed, resulting in denial of service.
ModificadaAlta (7.8)0.24%—Aveva Batch ManagementAveva Communication DriversAveva EdgeAveva Enterprise Licensing+915/11/202317/6/2026
This privilege escalation vulnerability, if exploited, cloud allow a local OS-authenticated user with standard privileges to escalate to System privilege on the machine where these products are installed, resulting in complete compromise of the target machine.
ModificadaAlta (7.5)47%—Aveva Intouch Access Anywhere23/12/202217/6/2026
AVEVA InTouch Access Anywhere versions 2020 R2 and older are vulnerable to a path traversal exploit that could allow an unauthenticated user with network access to read files on the system outside of the secure gateway web server.
ModificadaCrítica (9.9)0.97%—Aveva Intouch Access AnywhereAveva Plant Scada Access Anywhere23/5/202217/6/2026
Windows OS can be configured to overlay a “language bar” on top of any application. When this OS functionality is enabled, the OS language bar UI will be viewable in the browser alongside the AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere applications. It is possible to manipulate the Windows OS…
ModificadaMedia (5.5)0.18%—Aveva Intouch 2017Aveva Intouch 20209/6/202117/6/2026
The vulnerability could expose cleartext credentials from AVEVA InTouch Runtime 2020 R2 and all prior versions (WindowViewer) if an authorized, privileged user creates a diagnostic memory dump of the process and saves it to a non-protected location.
ModificadaAlta (7.5)14%—Aveva Indusoft WEB StudioAveva Intouch Machine Edition 201413/2/201917/6/2026
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. An unauthenticated remote user could use a specially crafted database connection configuration file to execute an arbitrary process on the server machine.
ModificadaCrítica (9.8)17%—Aveva Indusoft WEB StudioAveva Intouch Machine Edition 201413/2/201917/6/2026
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
ModificadaCrítica (9.8)3.7%—Aveva Indusoft WEB StudioAveva EdgeAveva Intouch Machine Edition 20142/11/201817/6/2026
InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with…
ModificadaCrítica (9.8)4.6%—Aveva Indusoft WEB StudioAveva EdgeAveva Intouch Machine Edition 20142/11/201817/6/2026
InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine…
ModificadaCrítica (9.8)5.4%—Aveva Intouch 2014Aveva Intouch 201724/7/201817/6/2026
AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges…
ModificadaCrítica (9.8)4.2%—Aveva Indusoft WEB StudioAveva Intouch Machine 201719/7/201817/6/2026
AVEVA InduSoft Web Studio v8.1 and v8.1SP1, and InTouch Machine Edition v2017 8.1 and v2017 8.1 SP1 a remote user could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed.
ModificadaCrítica (9.8)8.6%—Indusoft WEB StudioIndustrial-software Intouch Machine Edition 201718/4/201817/6/2026
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
ModificadaCrítica (9.8)5.8%—Schneider-electric Wonderware Indusoft WEB StudioSchneider-electric Wonderware Intouch13/11/201717/6/2026
A Stack-based Buffer Overflow issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 Patch 1 and prior versions, and InTouch Machine Edition v8.0 SP2 Patch 1 and prior versions. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution with high…
ModificadaCrítica (9.8)5.1%—Schneider-electric Wonderware Indusoft WEB StudioSchneider-electric Wonderware Intouch3/10/201717/6/2026
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing…
ModificadaMedia (5.3)0.55%—Aveva Wonderware Intouch Access Anywhere20/4/201717/6/2026
An Inadequate Encryption Strength issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The software will connect via Transport Layer Security without verifying the peer's SSL certificate properly.
ModificadaCrítica (9.8)2.4%—Aveva Wonderware Intouch Access Anywhere20/4/201717/6/2026
An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. Credentials may be exposed to external systems via specific URL parameters, as arbitrary destination addresses may be specified.
ModificadaAlta (8.8)0.96%—Aveva Wonderware Intouch Access Anywhere20/4/201717/6/2026
A Cross-Site Request Forgery issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The client request may be forged from a different site. This will allow an external site to access internal RDP systems on behalf of the currently logged in user.
ModificadaBaja (1.7)0.32%—Indusoft WEB StudioWonderware Intouch1/8/201517/6/2026
Schneider Electric InduSoft Web Studio before 7.1.3.5 Patch 5 and Wonderware InTouch Machine Edition through 7.1 SP3 Patch 4 use cleartext for project-window password storage, which allows local users to obtain sensitive information by reading a file.
ModificadaBaja (2.1)0.37%—Aveva EdgeSchneider-electric Wonderware Intouch 201429/3/201517/6/2026
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
ModificadaBaja (3.3)0.77%—Aveva EdgeSchneider-electric Wonderware Intouch 201429/3/201517/6/2026
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.
ModificadaMedia (5)2.4%—Aveva EdgeSchneider-electric Wonderware Intouch 201429/3/201517/6/2026
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack.
ModificadaBaja (2.1)0.37%—Aveva EdgeSchneider-electric Wonderware Intouch 201429/3/201517/6/2026
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by…
ModificadaAlta (10)6.2%—Schneider-electric Wonderware Intouch Access Anywhere Server10/1/201517/6/2026
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.
ModificadaMedia (6.9)0.63%—Invensys Wonderware Intouch13/10/201316/6/2026
Invensys Wonderware InTouch HMI 2012 R2 and earlier allows remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML…