Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2568▼ 304 respecto a la semana anterior
Críticas / altas1352▲ 100 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 7 respecto a la semana anterior
Sin puntuar (sin CVSS)56▼ 472 respecto a la semana anterior
8 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 1.2% | — | Schneider-electric Interactive Graphical Scada System Data Server | 9/2/2022 | 17/6/2026 | A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | |
| Modificada | Alta (7.5) | 1.3% | — | Schneider-electric Interactive Graphical Scada System Data Server | 9/2/2022 | 17/6/2026 | A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | |
| Modificada | Alta (7.5) | 19% | — | Schneider-electric Interactive Graphical Scada System Data Server | 9/2/2022 | 17/6/2026 | A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | |
| Modificada | Alta (7.5) | 18% | — | Schneider-electric Interactive Graphical Scada System Data Server | 9/2/2022 | 17/6/2026 | A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | |
| Modificada | Crítica (9.8) | 45% | — | Schneider-electric Interactive Graphical Scada System Data Server | 9/2/2022 | 17/6/2026 | A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | |
| Modificada | Crítica (9.8) | 3.5% | — | Schneider-electric Interactive Graphical Scada System Data Server | 9/2/2022 | 17/6/2026 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message.… | |
| Modificada | Crítica (9.8) | 3.5% | — | Schneider-electric Interactive Graphical Scada System Data Server | 9/2/2022 | 17/6/2026 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted… | |
| Modificada | Crítica (9.8) | 2.2% | — | Schneider-electric Interactive Graphical Scada System Data Server | 9/2/2022 | 17/6/2026 | A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and… |