Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2797▼ 203 respecto a la semana anterior
Críticas / altas1352▲ 28 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)255▼ 266 respecto a la semana anterior
6 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (8.8) | 2.0% | — | Grandstream Ht801 Firmware | 28/10/2021 | 17/6/2026 | An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host. | |
| Modificada | Alta (8.8) | 7.4% | — | Grandstream Ht801 Firmware | 28/10/2021 | 17/6/2026 | Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device.… | |
| Modificada | Alta (8.8) | 2.7% | — | Grandstream Ht801 FirmwareGrandstream Ht802 FirmwareGrandstream Ht812 FirmwareGrandstream Ht814 Firmware+2 | 29/7/2020 | 17/6/2026 | Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt. | |
| Modificada | Alta (7.5) | 3.4% | — | Grandstream Ht801 FirmwareGrandstream Ht802 FirmwareGrandstream Ht812 FirmwareGrandstream Ht814 Firmware+2 | 29/7/2020 | 17/6/2026 | Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication… | |
| Modificada | Alta (7.5) | 4.1% | — | Grandstream Ht801 FirmwareGrandstream Ht802 FirmwareGrandstream Ht812 FirmwareGrandstream Ht814 Firmware+2 | 29/7/2020 | 17/6/2026 | Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service. | |
| Modificada | Alta (7.8) | 5.5% | — | Grandstream Ht801 FirmwareGrandstream Ht802 FirmwareGrandstream Ht812 FirmwareGrandstream Ht814 Firmware+2 | 29/7/2020 | 17/6/2026 | Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message. |