Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2663▼ 380 respecto a la semana anterior
Críticas / altas1289▼ 36 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)244▼ 274 respecto a la semana anterior
–

13 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
AnalizadaAlta (7.5)0.39%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux ARM SL+131/12/202517/6/2026
An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.
ModificadaAlta (8.8)0.88%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+103/8/202317/6/2026
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
ModificadaAlta (8.8)0.88%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+1223/3/202317/6/2026
In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
ModificadaAlta (7.5)1.0%—Codesys Development SystemCodesys Edge GatewayCodesys GatewayCodesys HMI SL+624/6/202217/6/2026
In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.
ModificadaAlta (7.5)1.5%—Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+147/4/202217/6/2026
A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system.
ModificadaAlta (7.5)1.3%—Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+167/4/202217/6/2026
An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed.
ModificadaAlta (8.1)1.1%—Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+147/4/202217/6/2026
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.
ModificadaAlta (7.1)0.89%—Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+167/4/202217/6/2026
An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed,…
ModificadaMedia (6.5)1.0%—Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+167/4/202217/6/2026
An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash.
ModificadaAlta (8.8)0.28%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+815/8/201917/6/2026
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless…
ModificadaAlta (7.5)3.0%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+1419/2/201917/6/2026
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
ModificadaAlta (7.5)2.6%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+1119/2/201917/6/2026
Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.
ModificadaCrítica (9.8)1.3%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+829/1/201917/6/2026
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.