Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2987▼ 96 respecto a la semana anterior
Críticas / altas1458▲ 101 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)350▼ 160 respecto a la semana anterior
4 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 1.5% | — | Rockwellautomation Compactlogix 5370 FirmwareRockwellautomation Compact Guardlogix 5370 FirmwareRockwellautomation Compact Guardlogix 5380 FirmwareRockwellautomation Controllogix 5570 Firmware+2 | 16/12/2022 | 17/6/2026 | A vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS). | |
| Modificada | Alta (8.6) | 2.3% | — | Rockwellautomation Armor Compact Guardlogix 5370 FirmwareRockwellautomation Compact Guardlogix 5370 FirmwareRockwellautomation Compactlogix 5370 L1 FirmwareRockwellautomation Compactlogix 5370 L2 Firmware+5 | 27/7/2022 | 17/6/2026 | The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which… | |
| Modificada | Alta (8.6) | 2.1% | — | Rockwellautomation Compactlogix 5380 FirmwareRockwellautomation Compact Guardlogix 5380 FirmwareRockwellautomation Compactlogix 5480 FirmwareRockwellautomation Controllogix 5580 Firmware+5 | 2/6/2022 | 17/6/2026 | A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project… | |
| Modificada | Crítica (9.8) | 5.2% | — | Rockwellautomation Compactlogix 1768-l43 FirmwareRockwellautomation Compactlogix 1768-l45 FirmwareRockwellautomation Compactlogix 1769-l31 FirmwareRockwellautomation Compactlogix 1769-l32c Firmware+20 | 11/4/2022 | 17/6/2026 | An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the… |