Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2987▼ 96 respecto a la semana anterior
Críticas / altas1458▲ 101 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)350▼ 160 respecto a la semana anterior
–

5 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)0.95%—Schneider-electric Spacelynk FirmwareSchneider-electric Wiser FOR KNX FirmwareSchneider-electric Fellerlynk Firmware11/2/202217/6/2026
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)
ModificadaMedia (6.1)0.60%—Schneider-electric Spacelynk FirmwareSchneider-electric Wiser FOR KNX FirmwareSchneider-electric Fellerlynk Firmware9/2/202217/6/2026
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser…
ModificadaAlta (8.1)0.41%—Schneider-electric Spacelynk FirmwareSchneider-electric Wiser FOR KNX FirmwareSchneider-electric Fellerlynk Firmware9/2/202217/6/2026
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could induce users to perform unintended actions, leading to the override of the system�s configurations when an attacker persuades a user to visit a rogue website. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk)…
ModificadaCrítica (9.8)1.1%—Schneider-electric Spacelynk FirmwareSchneider-electric Wiser FOR KNX FirmwareSchneider-electric Fellerlynk Firmware9/2/202217/6/2026
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and…
ModificadaMedia (5.3)0.79%—Schneider-electric Spacelynk FirmwareSchneider-electric Wiser FOR KNX FirmwareSchneider-electric Fellerlynk Firmware9/2/202217/6/2026
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and…