Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas3026▼ 51 respecto a la semana anterior
Críticas / altas1412▲ 58 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)385▼ 125 respecto a la semana anterior
6 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Crítica (9.1) | 0.95% | — | Baxter Em2400 FirmwareBaxter Em1200 Firmware | 29/6/2020 | 17/6/2026 | Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI. | |
| Modificada | Media (6.1) | 0.36% | — | Baxter Em2400 FirmwareBaxter Em1200 Firmware | 29/6/2020 | 17/6/2026 | Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to the system the ability… | |
| Modificada | Media (6.1) | 0.33% | — | Baxter Em2400 FirmwareBaxter Em1200 Firmware | 29/6/2020 | 17/6/2026 | Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users from gaining access to the operating system and editing the application startup script. Successful exploitation of this vulnerability may allow an attacker to alter the… | |
| Modificada | Crítica (9.8) | 1.9% | — | Baxter Em2400 FirmwareBaxter Em1200 Firmware | 29/6/2020 | 17/6/2026 | Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix… | |
| Modificada | Media (6.1) | 0.36% | — | Baxter Em2400 FirmwareBaxter Em1200 Firmware | 29/6/2020 | 17/6/2026 | Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix… | |
| Modificada | Alta (7.5) | 0.95% | — | Baxter Em2400 FirmwareBaxter Em1200 Firmware | 29/6/2020 | 17/6/2026 | Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI. |