Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2855▼ 166 respecto a la semana anterior
Críticas / altas1379▲ 45 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)266▼ 260 respecto a la semana anterior
7 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.8) | 0.15% | — | Emerson Deltav Distributed Control System SQ Controller FirmwareEmerson Deltav Distributed Control System SX Controller FirmwareEmerson Se4002s1t2b6 High Side 40-pin Mass I/O Terminal Block FirmwareEmerson Se4003s2b4 16-pin Mass I/O Terminal Block Firmware+20 | 26/12/2022 | 17/6/2026 | Emerson DeltaV Distributed Control System (DCS) has insufficient verification of firmware integrity (an inadequate checksum approach, and no signature). This affects versions before 14.3 of DeltaV M-series, DeltaV S-series, DeltaV P-series, DeltaV SIS, and DeltaV CIOC/EIOC/WIOC IO cards. | |
| Modificada | Media (5.5) | 0.18% | — | Emerson Deltav Distributed Control SystemEmerson Deltav Distributed Control System SQ Controller FirmwareEmerson Deltav Distributed Control System SX Controller FirmwareEmerson Se4002s1t2b6 High Side 40-pin Mass I/O Terminal Block Firmware+21 | 26/7/2022 | 17/6/2026 | The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. Access to privileged operations on the maintenance port TELNET interface (23/TCP) on M-series and SIS (CSLS/LSNB/LSNG) nodes is controlled by means of utility passwords. These passwords are generated using… | |
| Modificada | Media (5.5) | 0.24% | — | Emerson Deltav Distributed Control System SQ Controller FirmwareEmerson Deltav Distributed Control System SX Controller FirmwareEmerson Se4002s1t2b6 High Side 40-pin Mass I/O Terminal Block FirmwareEmerson Se4003s2b4 16-pin Mass I/O Terminal Block Firmware+20 | 26/7/2022 | 17/6/2026 | The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. WIOC SSH provides access to a shell as root, DeltaV, or backup via hardcoded credentials. NOTE: this is different from CVE-2014-2350. | |
| Modificada | Media (5.5) | 0.24% | — | Emerson Deltav Distributed Control System SQ Controller FirmwareEmerson Deltav Distributed Control System SX Controller FirmwareEmerson Se4002s1t2b6 High Side 40-pin Mass I/O Terminal Block FirmwareEmerson Se4003s2b4 16-pin Mass I/O Terminal Block Firmware+20 | 26/7/2022 | 17/6/2026 | The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. TELNET on port 18550 provides access to a root shell via hardcoded credentials. This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350. | |
| Modificada | Media (5.5) | 0.24% | — | Emerson Deltav Distributed Control System SQ Controller FirmwareEmerson Deltav Distributed Control System SX Controller FirmwareEmerson Se4002s1t2b6 High Side 40-pin Mass I/O Terminal Block FirmwareEmerson Se4003s2b4 16-pin Mass I/O Terminal Block Firmware+20 | 26/7/2022 | 17/6/2026 | The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. FTP has hardcoded credentials (but may often be disabled in production). This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350. | |
| Modificada | Alta (7.8) | 0.22% | — | Emerson Deltav Distributed Control System | 26/7/2022 | 17/6/2026 | The Emerson DeltaV Distributed Control System (DCS) through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade (18508/TCP, 18518/TCP); Plug-and-Play (18510/UDP); Hawk services (18507/UDP); Management (18519/TCP);… | |
| Modificada | Media (5.5) | 0.19% | — | Emerson Deltav WorkstationEmerson Deltav Distributed Control System | 28/1/2022 | 17/6/2026 | A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition. |