| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Crítica (9.8) | 1.00% | — | Yokogawa Centum VP FirmwareYokogawa Centum VP Entry FirmwareYokogawa Exaopc | 11/3/2022 | 17/6/2026 | The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00 | |
| Modificada | Alta (7.8) | 0.22% | — | Yokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP FirmwareYokogawa Centum VP Entry Firmware+1 | 11/3/2022 | 17/6/2026 | The following Yokogawa Electric products contain insecure DLL loading issues. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. | |
| Modificada | Alta (8.8) | 0.95% | — | Yokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP FirmwareYokogawa Centum VP Entry Firmware+1 | 11/3/2022 | 17/6/2026 | CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from… | |
| Modificada | Alta (8.1) | 0.80% | — | Yokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP FirmwareYokogawa Centum VP Entry Firmware+1 | 11/3/2022 | 17/6/2026 | CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to… | |
| Modificada | Alta (7.8) | 0.22% | — | Yokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP FirmwareYokogawa Centum VP Entry Firmware+1 | 11/3/2022 | 17/6/2026 | 'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from… | |
| Modificada | Alta (8.1) | 0.80% | — | Yokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP FirmwareYokogawa Centum VP Entry Firmware+1 | 11/3/2022 | 17/6/2026 | CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource consumption. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to… | |
| Modificada | Alta (7.8) | 0.21% | — | Yokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP FirmwareYokogawa Centum VP Entry Firmware+1 | 11/3/2022 | 17/6/2026 | 'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc… | |
| Modificada | Alta (8.8) | 1.1% | — | Yokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP FirmwareYokogawa Centum VP Entry Firmware+1 | 11/3/2022 | 17/6/2026 | Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. | |
| Modificada | Crítica (9.8) | 0.97% | — | Yokogawa Centum VP FirmwareYokogawa Centum VP Entry FirmwareYokogawa Exaopc | 11/3/2022 | 17/6/2026 | The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00. | |
| Modificada | Alta (8.1) | 0.94% | — | Yokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP FirmwareYokogawa Centum VP Entry Firmware+1 | 11/3/2022 | 17/6/2026 | There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, andfrom R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. | |
| Modificada | Crítica (9.8) | 6.7% | — | Yokogawa Centum CS 1000 FirmwareYokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP Firmware+17 | 5/2/2020 | 17/6/2026 | Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and… | |
| Modificada | Crítica (9.8) | 4.2% | — | Yokogawa Centum CS 1000 FirmwareYokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP Firmware+17 | 5/2/2020 | 17/6/2026 | Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and… | |
| Modificada | Crítica (9.8) | 4.2% | — | Yokogawa Centum CS 1000 FirmwareYokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP Firmware+17 | 5/2/2020 | 17/6/2026 | Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and… |