Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2663▼ 380 respecto a la semana anterior
Críticas / altas1289▼ 36 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)244▼ 274 respecto a la semana anterior
26 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (4.8) | 0.96% | — | Siemens Scalance M-800 FirmwareSiemens Scalance S615 FirmwareSiemens Scalance Sc-600 FirmwareSiemens Scalance Sc622-2c Firmware+86 | 10/8/2022 | 17/6/2026 | Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. | |
| Modificada | Alta (7.5) | 1.7% | — | Siemens Scalance M-800 FirmwareSiemens Scalance S615 FirmwareSiemens Scalance W700 Ieee 802.11ax FirmwareSiemens Scalance W700 Ieee 802.11n Firmware+80 | 10/8/2022 | 17/6/2026 | Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. | |
| Modificada | Alta (7.2) | 1.8% | — | Siemens Scalance M-800 FirmwareSiemens Scalance S615 FirmwareSiemens Scalance Sc-600 FirmwareSiemens Scalance Sc622-2c Firmware+86 | 10/8/2022 | 17/6/2026 | Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. | |
| Modificada | Alta (8.7) | 1.9% | — | Siemens DK Standard Ethernet Controller Evaluation KIT FirmwareSiemens Ek-ertec 200 Evaulation KIT FirmwareSiemens Ek-ertec 200p Evaluation KIT FirmwareSiemens Ruggedcom Rm1224 Firmware+75 | 13/7/2021 | 17/6/2026 | Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. | |
| Modificada | Media (5.3) | 5.6% | — | Samsung Galaxy I9305 FirmwareArista C-250 FirmwareArista C-260 FirmwareArista C-230 Firmware+15 | 11/5/2021 | 17/6/2026 | An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP,… | |
| Modificada | Media (6.5) | 4.9% | — | Samsung Galaxy I9305 FirmwareArista C-250 FirmwareArista C-260 FirmwareArista C-230 Firmware+14 | 11/5/2021 | 17/6/2026 | An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 (i.e., LLC/SNAP) header for EAPOL. An adversary can abuse this to inject arbitrary network packets independent of the… | |
| Modificada | Media (6.5) | 2.9% | — | Alfa Awus036h FirmwareSiemens Scalance W1748-1 FirmwareSiemens Scalance W1750d FirmwareSiemens Scalance W1788-1 Firmware+190 | 11/5/2021 | 17/6/2026 | An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration. | |
| Modificada | Media (5.3) | 6.5% | — | NetbsdDebian LinuxArista C-100 FirmwareArista C-110 Firmware+162 | 11/5/2021 | 17/6/2026 | An issue was discovered in the kernel in NetBSD 7.1. An Access Point (AP) forwards EAPOL frames to other clients even though the sender has not yet successfully authenticated to the AP. This might be abused in projected Wi-Fi networks to launch denial-of-service attacks against connected clients and makes it easier to… | |
| Modificada | Baja (3.5) | 3.6% | — | Ieee 802.11Linux Mac80211Microsoft Windows 10Microsoft Windows 7+177 | 11/5/2021 | 17/6/2026 | The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary… | |
| Modificada | Baja (2.6) | 2.6% | — | Ieee 802.11Linux Mac80211Debian LinuxArista C-100 Firmware+164 | 11/5/2021 | 17/6/2026 | The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that all fragments of a frame are encrypted under the same key. An adversary can abuse this to decrypt selected fragments when another device sends fragmented frames and the WEP, CCMP, or… | |
| Modificada | Baja (3.5) | 5.8% | — | Ieee 802.11Debian LinuxLinux Mac80211Arista C-250 Firmware+20 | 11/5/2021 | 17/6/2026 | The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that received fragments be cleared from memory after (re)connecting to a network. Under the right circumstances, when another device sends fragmented frames encrypted using WEP, CCMP, or… | |
| Modificada | Media (5.9) | 64% | — | OpensslDebian LinuxFreebsdNetapp Active IQ Unified Manager+102 | 25/3/2021 | 17/6/2026 | An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer… | |
| Modificada | Alta (8.8) | 0.95% | — | Siemens Ruggedcom Rm1224 FirmwareSiemens Scalance M-800 FirmwareSiemens Scalance S615 FirmwareSiemens Scalance X300wg Firmware+11 | 15/3/2021 | 17/6/2026 | A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions… | |
| Modificada | Alta (7.5) | 1.4% | — | Siemens Scalance Xc-200 FirmwareSiemens Scalance Xf-200 FirmwareSiemens Scalance Xp-200 FirmwareSiemens Scalance Xb-200 Firmware+9 | 14/4/2020 | 17/6/2026 | A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO,… | |
| Modificada | Alta (7.5) | 1.5% | — | Siemens DK Standard Ethernet ControllerSiemens Profinet DriverSiemens Simatic IPC SupportSiemens Ek-ertec 200 Firmware+48 | 11/2/2020 | 17/6/2026 | Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack.… | |
| Modificada | Media (5.4) | 0.83% | — | Siemens Scalance Xc-200 FirmwareSiemens Scalance Xf-200 FirmwareSiemens Scalance Xp-200 FirmwareSiemens Scalance X-200irt Firmware+4 | 11/2/2020 | 17/6/2026 | A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS… | |
| Modificada | Media (6.5) | 1.2% | — | Siemens Scalance Xb-200 FirmwareSiemens Scalance Xc-200 FirmwareSiemens Scalance Xf-200ba FirmwareSiemens Scalance Xp-200 Firmware+1 | 13/8/2019 | 17/6/2026 | A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The… | |
| Modificada | Crítica (9.1) | 1.3% | — | Siemens Scalance X-200 FirmwareSiemens Scalance X-300 FirmwareSiemens Scalance Xp-200 FirmwareSiemens Scalance Xc-200 Firmware+1 | 26/3/2019 | 17/6/2026 | The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior. | |
| Modificada | Alta (8.8) | 1.1% | — | Siemens Scalance Xb-200 FirmwareSiemens Scalance Xc-200 FirmwareSiemens Scalance Xp-200 FirmwareSiemens Scalance Xr300-wg Firmware+3 | 26/12/2017 | 17/6/2026 | After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions. This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions. | |
| Modificada | Crítica (9.8) | 2.4% | — | Jantek Jtc-200 Firmware | 13/10/2017 | 17/6/2026 | An Improper Authentication issue was discovered in JanTek JTC-200, all versions. The improper authentication could provide an undocumented BusyBox Linux shell accessible over the TELNET service without any authentication. | |
| Modificada | Alta (8) | 0.43% | — | Jantek Jtc-200 Firmware | 13/10/2017 | 17/6/2026 | A Cross-site Request Forgery issue was discovered in JanTek JTC-200, all versions. An attacker could perform actions with the same permissions as a victim user, provided the victim has an active session and is induced to trigger the malicious request. | |
| Modificada | Alta (7.8) | 3.0% | — | Camtron Cmnc-200 FirmwareCamtron Cmnc-200Tecvoz Cmnc-200 FirmwareTecvoz Cmnc-200 | 17/11/2010 | 16/6/2026 | The web server on the Camtron CMNC-200 Full HD IP Camera and TecVoz CMNC-200 Megapixel IP Camera with firmware 1.102A-008 allows remote attackers to cause a denial of service (device reboot) via a large number of requests in a short time interval. | |
| Modificada | Alta (10) | 9.4% | — | Camtron Cmnc-200 FirmwareCamtron Cmnc-200Tecvoz Cmnc-200 FirmwareTecvoz Cmnc-200 | 17/11/2010 | 16/6/2026 | The Linux installation on the Camtron CMNC-200 Full HD IP Camera and TecVoz CMNC-200 Megapixel IP Camera with firmware 1.102A-008 has a default password of m for the root account, and a default password of merlin for the mg3500 account, which makes it easier for remote attackers to obtain access via the TELNET… | |
| Modificada | Alta (10) | 4.2% | — | Camtron Cmnc-200 FirmwareCamtron Cmnc-200Tecvoz Cmnc-200 FirmwareTecvoz Cmnc-200 | 17/11/2010 | 16/6/2026 | The web-based administration interface on the Camtron CMNC-200 Full HD IP Camera and TecVoz CMNC-200 Megapixel IP Camera with firmware 1.102A-008 allows remote attackers to bypass authentication via a // (slash slash) at the beginning of a URI, as demonstrated by the //system.html URI. | |
| Modificada | Alta (7.8) | 16% | — | Camtron Cmnc-200 FirmwareCamtron Cmnc-200Tecvoz Cmnc-200 FirmwareTecvoz Cmnc-200 | 17/11/2010 | 16/6/2026 | Directory traversal vulnerability in the web-based administration interface on the Camtron CMNC-200 Full HD IP Camera and TecVoz CMNC-200 Megapixel IP Camera with firmware 1.102A-008 allows remote attackers to read arbitrary files via a .. (dot dot) in the URI. |