Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas3007▼ 67 respecto a la semana anterior
Críticas / altas1403▲ 50 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)390▼ 120 respecto a la semana anterior
11 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Aplazada | Alta (7.4) | 0.80% | — | Edimax Br-6208acAI | 3/5/2026 | 17/6/2026 | A vulnerability was detected in Edimax BR-6208AC up to 1.02. Affected is an unknown function of the file /goform/setWAN. Performing a manipulation of the argument pptpDfGateway results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted early… | |
| Aplazada | Baja (2.1) | 2.4% | — | Edimax Br-6208acAI | 3/5/2026 | 17/6/2026 | A security flaw has been discovered in Edimax BR-6208AC 1.02. The impacted element is the function setWAN of the file /goform/setWAN of the component L2TP Mode. The manipulation of the argument L2TPUserName results in command injection. It is possible to launch the attack remotely. The exploit has been released to the… | |
| Analizada | Media (5.5) | 0.67% | — | Edimax Br-6208ac Firmware | 6/2/2026 | 17/6/2026 | A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the argument Username/Password results in use of default credentials. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor… | |
| Analizada | Crítica (9.8) | 27% | — | Edimax Br-6208ac Firmware | 9/1/2026 | 17/6/2026 | EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution. | |
| Modificada | Baja (2) | 0.26% | — | Edimax Br-6208ac Firmware | 30/12/2025 | 17/6/2026 | A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The… | |
| Modificada | Media (5.5) | 5.1% | — | Edimax Br-6208ac Firmware | 30/12/2025 | 17/6/2026 | A security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formRoute of the component Web-based Configuration Interface. The manipulation of the argument strIp/strMask/strGateway results in command injection. The attack can be… | |
| Analizada | Media (5.5) | 3.8% | — | Edimax Br-6208ac Firmware | 30/12/2025 | 17/6/2026 | A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The… | |
| Analizada | Baja (2.1) | 0.53% | — | Edimax Br-6208ac Firmware | 19/12/2025 | 17/6/2026 | A vulnerability was detected in Edimax BR-6208AC 1.02. This impacts the function handle_retr of the component FTP Daemon Service. The manipulation results in path traversal. The attack may be launched remotely. The exploit is now public and may be used. Edimax confirms this issue: "This product is no longer available… | |
| Modificada | Alta (8.8) | 0.91% | — | Edimax Br-6208ac V1 Firmware | 27/8/2019 | 17/6/2026 | Edimax BR-6208AC V1 devices have Insufficient Compartmentalization between a host network and a guest network that are established by the same device. In order to transfer data from the host network to the guest network, the sender joins and then leaves an IGMP group. After it leaves, the router (following the IGMP… | |
| Modificada | Alta (8.8) | 0.91% | — | Edimax Br-6208ac V1 Firmware | 27/8/2019 | 17/6/2026 | Edimax BR-6208AC V1 devices have Insufficient Compartmentalization between a host network and a guest network that are established by the same device. A DHCP Request is sent to the router with a certain Transaction ID field. Following the DHCP protocol, the router responds with an ACK or NAK message. Studying the NAK… | |
| Modificada | Alta (8.8) | 0.97% | — | Edimax Br-6208ac V1 Firmware | 27/8/2019 | 17/6/2026 | Edimax BR-6208AC V1 devices have Insufficient Compartmentalization between a host network and a guest network that are established by the same device. They forward ARP requests, which are sent as broadcast packets, between the host and the guest networks. To use this leakage as a direct covert channel, the sender can… |