Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2703▼ 615 respecto a la semana anterior
Críticas / altas1293▼ 208 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)291▼ 219 respecto a la semana anterior
18 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (6.5) | 0.35% | — | Schneider-electric Modicon M340 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 Firmware | 12/6/2024 | 17/6/2026 | CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem. | |
| Modificada | Alta (7.5) | 0.61% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 FirmwareSchneider-electric Modicon M340 Bmxp3420102 Firmware+10 | 22/11/2022 | 17/6/2026 | A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100… | |
| Modificada | Alta (7.5) | 1.0% | — | Schneider-electric Modicon M340 Bmxp342020 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoc0401 Firmware+10 | 11/2/2022 | 17/6/2026 | A CWE-787: Out-of-bounds Write vulnerability exists that could cause denial of service when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H),… | |
| Modificada | Alta (7.5) | 1.0% | — | Schneider-electric Modicon M340 Bmxp342020 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoc0401 Firmware+10 | 11/2/2022 | 17/6/2026 | A CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules:… | |
| Modificada | Alta (7.5) | 0.96% | — | Schneider-electric Modicon M340 Bmxp342020 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoc0401 Firmware+10 | 11/2/2022 | 17/6/2026 | A CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web root directory to leak when an attacker sends a HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet… | |
| Modificada | Media (5.3) | 1.1% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+15 | 11/12/2020 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause denial of HTTP and FTP services when a… | |
| Modificada | Media (5.3) | 0.91% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+16 | 11/12/2020 | 17/6/2026 | A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted… | |
| Modificada | Crítica (9.8) | 2.3% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+19 | 11/12/2020 | 17/6/2026 | A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller… | |
| Modificada | Alta (7.5) | 1.2% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+16 | 11/12/2020 | 17/6/2026 | A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a… | |
| Modificada | Alta (7.5) | 1.2% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+6 | 11/12/2020 | 17/6/2026 | A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to… | |
| Modificada | Alta (7.5) | 1.5% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+17 | 11/12/2020 | 17/6/2026 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause… | |
| Modificada | Crítica (9.8) | 2.3% | — | Schneider-electric Modicon M340 Bmxp3420302 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 Firmware+12 | 1/12/2020 | 17/6/2026 | CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests. | |
| Modificada | Media (5.4) | 0.56% | — | Schneider-electric Bmxnoc0401 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoe0110h Firmware+7 | 21/3/2019 | 17/6/2026 | Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC… | |
| Modificada | Media (5.4) | 0.87% | — | Schneider-electric Bmxnoc0401 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoe0110h Firmware+7 | 21/3/2019 | 17/6/2026 | Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser… | |
| Modificada | Alta (7.5) | 4.8% | — | Schneider-electric Bmxnoc0401 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoe0110h Firmware+11 | 30/6/2017 | 17/6/2026 | A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially… | |
| Modificada | Alta (10) | 7.4% | — | Schneider-electric Bmxnoc0401Schneider-electric Bmxnoe0100Schneider-electric Bmxnoe0100hSchneider-electric Bmxnoe0110+9 | 21/12/2015 | 17/6/2026 | Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data. | |
| Modificada | Alta (10) | 9.5% | — | Schneider-electric Stbnic2212 FirmwareSchneider-electric Stbnip2212 FirmwareSchneider-electric Tsxetc0101 FirmwareSchneider-electric Tsxetc100 Firmware+39 | 3/10/2014 | 17/6/2026 | Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7,… | |
| Modificada | Alta (10) | 3.9% | — | Schneider-electric Quantum Ethernet Module 140cpu65150Schneider-electric Quantum Ethernet Module 140cpu65160Schneider-electric Quantum Ethernet Module 140cpu65260Schneider-electric Quantum Ethernet Module 140noe77100+17 | 17/12/2011 | 16/6/2026 | The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4)… |