Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas3006▼ 69 respecto a la semana anterior
Críticas / altas1420▲ 54 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)382▼ 128 respecto a la semana anterior
11 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Aplazada | Media (6.5) | 0.22% | — | Mitsubishielectric Genesis64AIMitsubishielectric Iconics SuiteAIMitsubishielectric MobilehmiAIMitsubishielectric Hyper HistorianAI+6 | 15/5/2025 | 17/6/2026 | Execution with Unnecessary Privileges vulnerability in multiple services of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior,… | |
| Aplazada | Media (6.7) | 0.19% | — | Mitsubishielectric Genesis64AIMitsubishielectric Iconics SuiteAIMitsubishielectric Hyper HistorianAIMitsubishielectric MobilehmiAI+4 | 4/7/2024 | 17/6/2026 | Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi… | |
| Modificada | Alta (7.5) | 2.0% | — | Mitsubishielectric MC WorksMitsubishielectric MC Works32Iconics Energy AnalytixIconics Facility Analytix+7 | 16/7/2020 | 17/6/2026 | A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS… | |
| Modificada | Crítica (9.1) | 3.0% | — | Mitsubishielectric MC Works32Mitsubishielectric MC Works64Iconics Energy AnalytixIconics Facility Analytix+7 | 16/7/2020 | 17/6/2026 | A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform… | |
| Modificada | Crítica (9.8) | 3.9% | — | Mitsubishielectric MC WorksMitsubishielectric MC Works32Iconics Energy AnalytixIconics Facility Analytix+7 | 16/7/2020 | 17/6/2026 | A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32… | |
| Modificada | Alta (7.5) | 3.6% | — | Mitsubishielectric MC WorksMitsubishielectric MC Works32Iconics Energy AnalytixIconics Facility Analytix+7 | 16/7/2020 | 17/6/2026 | A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS… | |
| Modificada | Crítica (9.8) | 29% | — | Mitsubishielectric MC WorksMitsubishielectric MC Works32Iconics Energy AnalytixIconics Facility Analytix+7 | 16/7/2020 | 17/6/2026 | A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64,… | |
| Modificada | Media (4.4) | 0.21% | — | Iconics Genesis32Iconics Bizviz | 31/7/2012 | 16/6/2026 | The lockout-recovery feature in the Security Configurator component in ICONICS GENESIS32 9.22 and earlier and BizViz 9.22 and earlier uses an improper encryption algorithm for generation of an authentication code, which allows local users to bypass intended access restrictions and obtain administrative access by… | |
| Modificada | Alta (10) | 4.3% | — | Iconics Genesis32Iconics Bizviz | 18/4/2012 | 16/6/2026 | Buffer overflow in the Security Login ActiveX controls in ICONICS GENESIS32 8.05, 9.0, 9.1, and 9.2 and BizViz 8.05, 9.0, 9.1, and 9.2 allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a long password. | |
| Modificada | Alta (9.3) | 2.7% | — | Iconics BizvizIconics Genesis32 | 18/4/2012 | 16/6/2026 | The GENESIS32 IcoSetServer ActiveX control in ICONICS GENESIS32 9.21 and BizViz 9.21 configures the trusted zone on the basis of user input, which allows remote attackers to execute arbitrary code via a crafted web site, related to a "Workbench32/WebHMI component SetTrustedZone Policy vulnerability." | |
| Modificada | Alta (9.3) | 38% | — | Iconics BizvizIconics Genesis32 | 13/5/2011 | 16/6/2026 | Stack-based buffer overflow in the SetActiveXGUID method in the VersionInfo ActiveX control in GenVersion.dll 8.0.138.0 in the WebHMI subsystem in ICONICS BizViz 9.x before 9.22 and GENESIS32 9.x before 9.22 allows remote attackers to execute arbitrary code via a long string in the argument. NOTE: some of these… |