5 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (6.8) | 0.47% | — | Roche Accu-chek Inform II FirmwareRoche Cobas H 232 FirmwareRoche Coaguchek PRO II FirmwareRoche Coaguchek XS Plus Firmware+1 | 20/11/2018 | 17/6/2026 | An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 (Serial number below… | |
| Modificada | Alta (7.4) | 0.58% | — | Roche Accu-chek Inform II FirmwareRoche Cobas H 232 FirmwareRoche Coaguchek PRO II Firmware | 20/11/2018 | 17/6/2026 | An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, and cobas h 232 before 04.00.04 (Serial number above KQ0400000 or KS0400000). Improper access control allows attackers in… | |
| Modificada | Crítica (9.6) | 0.97% | — | Roche Accu-chek Inform II FirmwareRoche Cobas H 232 FirmwareRoche Coaguchek PRO II FirmwareRoche Coaguchek XS Plus Firmware+1 | 20/11/2018 | 17/6/2026 | An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 (Serial Number below… | |
| Modificada | Alta (8.8) | 0.71% | — | Roche Accu-chek Inform II FirmwareRoche Cobas H 232 FirmwareRoche Coaguchek FirmwareRoche Base Unit HUB Firmware | 20/11/2018 | 17/6/2026 | An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Weak access credentials may enable attackers in the adjacent network to gain unauthorized service access via a service interface. | |
| Modificada | Alta (8) | 0.67% | — | Roche Accu-chek Inform II FirmwareRoche Cobas H 232 FirmwareRoche Coaguchek FirmwareRoche Base Unit HUB Firmware | 20/11/2018 | 17/6/2026 | An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Insecure permissions in a service interface may allow authenticated attackers in the adjacent network to execute arbitrary commands on the operating system. |