Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2989▼ 73 respecto a la semana anterior
Críticas / altas1415▲ 65 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)382▼ 128 respecto a la semana anterior
–

23 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaMedia (4.9)0.85%—Wago 750-331 FirmwareWago 750-8202 FirmwareWago 750-8202/000-011 FirmwareWago 750-8202/000-012 Firmware+7226/6/202317/6/2026
Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a specifically crafted packet to the CODESYS V2 runtime.
ModificadaMedia (4.9)0.79%—Wago 750-331 FirmwareWago 750-8202 FirmwareWago 750-8202/000-011 FirmwareWago 750-8202/000-012 Firmware+7226/6/202317/6/2026
Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a malformed packet.
AnalizadaAlta (7.8)0.17%—Pilz PMCCodesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000+6026/12/202217/6/2026
In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device.
ModificadaAlta (7.5)0.73%—Wago 750-8100 FirmwareWago 750-8101 FirmwareWago 750-8101/000-010 FirmwareWago 750-8101/025-000 Firmware+7417/10/202217/6/2026
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
AnalizadaMedia (6.5)0.85%—Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+2626/10/202117/6/2026
A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition.
AnalizadaAlta (8.1)0.88%—Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+2626/10/202117/6/2026
A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite.
AnalizadaAlta (7.5)2.7%—Wago 750-8202 FirmwareWago 750-8203 FirmwareWago 750-8204 FirmwareWago 750-8206 Firmware+1126/10/202117/6/2026
In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.
AnalizadaAlta (7.5)14%—Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+2426/10/202117/6/2026
In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests may cause a Null pointer dereference in the CODESYS web server and may result in a denial-of-service condition.
AnalizadaAlta (7.5)0.93%—Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+2426/10/202117/6/2026
In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests can trigger a parser error. Since the parser result is not checked under all conditions, a pointer dereference with an invalid address can occur. This leads to a denial of service situation.
AnalizadaCrítica (9.1)1.1%—Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+2426/10/202117/6/2026
Crafted web server requests can be utilised to read partial stack or heap memory or may trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22.
AnalizadaAlta (7.5)8.4%—Wago 750-8214 FirmwareWago 750-8216 FirmwareWago 750-8217 FirmwareWago 750-8213 Firmware+2426/10/202117/6/2026
Crafted web server requests may cause a heap-based buffer overflow and could therefore trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22.
AnalizadaAlta (7.5)7.2%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2525/5/202117/6/2026
CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation.
AnalizadaCrítica (9.1)1.2%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2425/5/202117/6/2026
CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Read.
AnalizadaCrítica (9.8)1.2%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2425/5/202117/6/2026
CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write.
AnalizadaCrítica (9.8)1.2%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2425/5/202117/6/2026
CODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check.
AnalizadaAlta (7.5)1.0%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2425/5/202117/6/2026
CODESYS V2 Web-Server before 1.1.9.20 has a a Buffer Copy without Checking the Size of the Input.
AnalizadaCrítica (9.8)1.4%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2425/5/202117/6/2026
CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.
AnalizadaCrítica (9.8)1.3%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2425/5/202117/6/2026
CODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow.
AnalizadaCrítica (9.8)1.3%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2425/5/202117/6/2026
CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow.
AnalizadaAlta (7.5)7.4%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2525/5/202117/6/2026
CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow.
AnalizadaMedia (5.3)0.27%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2425/5/202117/6/2026
CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command.
AnalizadaMedia (6.5)1.1%—Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+2324/5/202117/6/2026
On WAGO PFC200 devices in different firmware versions with special crafted packets an authorised attacker with network access to the device can access the file system with higher privileges.
AnalizadaAlta (7.5)1.0%—Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+2324/5/202117/6/2026
On WAGO PFC200 devices in different firmware versions with special crafted packets an attacker with network access to the device could cause a denial of service for the login service of the runtime.