Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas3006▼ 69 respecto a la semana anterior
Críticas / altas1420▲ 54 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)382▼ 128 respecto a la semana anterior
5 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (6.5) | 0.73% | — | Aeotec Zw090-aSamsung Sth-eth-200Silabs Uzb-7Zooz Zst10+2 | 10/1/2022 | 17/6/2026 | Z-Wave devices using Silicon Labs 500 and 700 series chipsets, including but not likely limited to the SiLabs UZB-7 version 7.00, ZooZ ZST10 version 6.04, Aeon Labs ZW090-A version 3.95, and Samsung STH-ETH-200 version 6.04, are susceptible to denial of service via malformed routing messages. | |
| Modificada | Media (6.5) | 0.70% | — | Silabs Uzb-7Silabs 700 Series Firmware | 10/1/2022 | 17/6/2026 | Z-Wave devices based on Silicon Labs 700 series chipsets using S2 do not adequately authenticate or encrypt FIND_NODE_IN_RANGE frames, allowing a remote, unauthenticated attacker to inject a FIND_NODE_IN_RANGE frame with an invalid random payload, denying service by blocking the processing of upcoming events. | |
| Modificada | Alta (7.9) | 0.42% | — | HP 700 Series FirmwareHP 800 Series FirmwareHP Z240 FirmwareHP Z238 Firmware+3 | 4/3/2016 | 17/6/2026 | Sure Start on HP Commercial PCs 2015 allows local users to cause a denial of service (BIOS recovery failure) by leveraging administrative access. | |
| Modificada | Alta (10) | 5.9% | — | Siemens Scalance W700 Series FirmwareSiemens Scalance W744-1Siemens Scalance W744-1proSiemens Scalance W746-1+13 | 1/8/2013 | 16/6/2026 | Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection. | |
| Modificada | Media (6.6) | 0.95% | — | Siemens Scalance W700 Series FirmwareSiemens Scalance W744-1Siemens Scalance W744-1proSiemens Scalance W746-1+13 | 1/8/2013 | 16/6/2026 | Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship. |