Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2632▼ 455 respecto a la semana anterior
Críticas / altas1285▼ 65 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)235▼ 275 respecto a la semana anterior
–

7 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)1.3%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
ModificadaCrítica (9.8)2.1%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
ModificadaCrítica (9.8)1.5%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.
ModificadaAlta (7.5)1.3%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.
ModificadaCrítica (9.8)1.9%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.
ModificadaCrítica (9.8)3.7%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
ModificadaAlta (8.8)3.2%—Schneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 FirmwareSchneider-electric 140cpu43412u FirmwareSchneider-electric 140cpu65160 Firmware+918/4/201817/6/2026
A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious firmware.