| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Crítica (9.8) | 1.2% | — | Myscada Mypro | 23/12/2021 | 17/6/2026 | An additional, nondocumented administrative account exists in mySCADA myPRO Versions 8.20.0 and prior that is not exposed through the web interface, which cannot be deleted or changed through the regular web interface. | |
| Modificada | Crítica (9.8) | 1.5% | — | Myscada Mypro | 23/12/2021 | 17/6/2026 | An unauthenticated remote attacker can access mySCADA myPRO Versions 8.20.0 and prior without any form of authentication or authorization. | |
| Modificada | Crítica (9.8) | 1.2% | — | Myscada Mypro | 23/12/2021 | 17/6/2026 | mySCADA myPRO: Versions 8.20.0 and prior has a feature where the firmware can be updated, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. | |
| Modificada | Crítica (9.8) | 1.2% | — | Myscada Mypro | 23/12/2021 | 17/6/2026 | mySCADA myPRO: Versions 8.20.0 and prior has a feature to send emails, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. | |
| Modificada | Crítica (9.8) | 1.2% | — | Myscada Mypro | 23/12/2021 | 17/6/2026 | mySCADA myPRO: Versions 8.20.0 and prior has a feature where the password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. | |
| Modificada | Crítica (9.8) | 1.2% | — | Myscada Mypro | 23/12/2021 | 17/6/2026 | mySCADA myPRO: Versions 8.20.0 and prior has a feature where the API password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. | |
| Modificada | Alta (7.8) | 38% | — | Myscada Mydesigner | 19/11/2021 | 17/6/2026 | mySCADA myDESIGNER Versions 8.20.0 and prior fails to properly validate contents of an imported project file, which may make the product vulnerable to a path traversal payload. This vulnerability may allow an attacker to plant files on the file system in arbitrary locations or overwrite existing files, resulting in… | |
| Modificada | Crítica (9.8) | 15% | — | Ipack Scada Automation | 16/11/2021 | 17/6/2026 | Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0. | |
| Modificada | Media (4.3) | 0.70% | — | Advantech Webaccess Scada | 15/10/2021 | 17/6/2026 | An authenticated user using Advantech WebAccess SCADA in versions 9.0.3 and prior can use API functions to disclose project names and paths from other users. | |
| Modificada | Alta (7.8) | 1.3% | 💥 PoC | Laquisscada Scada | 4/10/2021 | 17/6/2026 | LCDS LAquis SCADA through 4.3.1.1085 is vulnerable to a control bypass and path traversal. If an attacker can get a victim to load a malicious els project file and use the play feature, then the attacker can bypass a consent popup and write arbitrary files to OS locations where the user has permission, leading to code… | |
| Modificada | Alta (7.8) | 11% | — | Myscada Mydesigner | 4/10/2021 | 17/6/2026 | mySCADA myDESIGNER 8.20.0 and below allows Directory Traversal attacks when importing project files. If an attacker can trick a victim into importing a malicious mep file, then they gain the ability to write arbitrary files to OS locations where the user has permission. This would typically lead to code execution. | |
| Modificada | Alta (7.5) | 2.6% | — | Opcfoundation Local Discover ServerSiemens Simatic Process Historian OPC UA Server FirmwareSiemens Simatic NET PCSiemens Simatic Wincc+3 | 27/8/2021 | 17/6/2026 | In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer. | |
| Modificada | Crítica (9.8) | 1.9% | — | Advantech Webaccess/scada | 10/8/2021 | 17/6/2026 | The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1). | |
| Modificada | Media (6.1) | 0.64% | — | Advantech Webaccess/scada | 10/8/2021 | 17/6/2026 | UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA… | |
| Modificada | Media (6.5) | 1.1% | — | Advantech Webaccess/scada | 10/8/2021 | 17/6/2026 | The affected product is vulnerable to a relative path traversal condition, which may allow an attacker access to unauthorized files and directories on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1). | |
| Modificada | Media (6.1) | 0.70% | — | Advantech Webaccess/scada | 18/6/2021 | 17/6/2026 | Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage. | |
| Modificada | Media (6.5) | 2.1% | — | Advantech Webaccess/scada | 18/6/2021 | 17/6/2026 | Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system. | |
| Modificada | Alta (7.8) | 1.4% | — | Schneider-electric Interactive Graphical Scada System | 11/6/2021 | 17/6/2026 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition. | |
| Modificada | Alta (7.8) | 0.66% | — | Schneider-electric Interactive Graphical Scada System | 11/6/2021 | 17/6/2026 | A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is… | |
| Modificada | Alta (7.8) | 1.2% | — | Schneider-electric Interactive Graphical Scada System | 11/6/2021 | 17/6/2026 | A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplied input data, when a malicious CGF file is imported to IGSS Definition. | |
| Modificada | Alta (7.8) | 1.2% | — | Schneider-electric Interactive Graphical Scada System | 11/6/2021 | 17/6/2026 | A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file is imported to IGSS Definition. | |
| Modificada | Alta (7.8) | 1.2% | — | Schneider-electric Interactive Graphical Scada System | 11/6/2021 | 17/6/2026 | A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation of user-supplied input data, when a malicious CGF file is imported to IGSS Definition. | |
| Modificada | Alta (7.8) | 1.3% | — | Schneider-electric Interactive Graphical Scada System | 11/6/2021 | 17/6/2026 | A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied input data, when a malicious CGF file is imported to IGSS Definition. | |
| Modificada | Alta (7.8) | 1.3% | — | Schneider-electric Interactive Graphical Scada System | 11/6/2021 | 17/6/2026 | A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation, when a malicious CGF file is imported to IGSS Definition. | |
| Modificada | Alta (7.8) | 1.3% | — | Schneider-electric Interactive Graphical Scada System | 11/6/2021 | 17/6/2026 | A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied data, when a malicious CGF file is imported to IGSS Definition. |