Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2696▼ 543 respecto a la semana anterior
Críticas / altas1264▼ 228 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)262▼ 241 respecto a la semana anterior
–

787 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)0.32%—Schneider-electric Wiser Smart Eer21000 FirmwareSchneider-electric Wiser Smart Eer21001 Firmware2/6/202217/6/2026
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
ModificadaAlta (8.2)0.79%—Schneider-electric Wiser Smart Eer21000 FirmwareSchneider-electric Wiser Smart Eer21001 Firmware2/6/202217/6/2026
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
ModificadaCrítica (9.8)1.0%—Schneider-electric Wiser Smart Eer21000 FirmwareSchneider-electric Wiser Smart Eer21001 Firmware2/6/202217/6/2026
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
ModificadaCrítica (9.8)1.2%—Schneider-electric Wiser Smart Eer21000 FirmwareSchneider-electric Wiser Smart Eer21001 Firmware2/6/202217/6/2026
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
ModificadaMedia (6.5)0.73%—Schneider-electric Wiser Smart Eer21000 FirmwareSchneider-electric Wiser Smart Eer21001 Firmware2/6/202217/6/2026
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
ModificadaAlta (8.8)1.2%—Schneider-electric Powerlogic ION Setup Firmware2/6/202217/6/2026
A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
ModificadaCrítica (9.8)2.4%—ATT XmillSchneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect14/4/202217/6/2026
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or…
ModificadaMedia (5.5)0.96%—Schneider-electric Scadapack Workbench13/4/202217/6/2026
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a remote system controlled by an attacker.…
ModificadaAlta (7.8)26%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect13/4/202217/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software.…
ModificadaCrítica (9.8)3.1%—Schneider-electric Struxureware Data Center Expert13/4/202217/6/2026
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
ModificadaCrítica (9.8)2.2%—Schneider-electric Struxureware Data Center Expert13/4/202217/6/2026
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
ModificadaAlta (7.8)1.0%—Schneider-electric Software Update13/4/202217/6/2026
A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneider Electric Software…
ModificadaMedia (6.8)0.25%—Belden Tofino Xenon Security Appliance FirmwareBelden Tofino Argon Fa-tsa-220-tx/mm FirmwareBelden Tofino Argon Fa-tsa-220-tx/tx FirmwareBelden Tofino Argon Fa-tsa-220-mm/tx Firmware+93/4/202217/6/2026
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of…
ModificadaAlta (7.5)0.88%—Belden Tofino Xenon Security Appliance FirmwareBelden Tofino Argon Fa-tsa-220-tx/mm FirmwareBelden Tofino Argon Fa-tsa-220-tx/tx FirmwareBelden Tofino Argon Fa-tsa-220-mm/tx Firmware+93/4/202217/6/2026
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.
ModificadaCrítica (9.8)0.90%—Belden Tofino Xenon Security Appliance FirmwareBelden Tofino Argon Fa-tsa-220-tx/mm FirmwareBelden Tofino Argon Fa-tsa-220-tx/tx FirmwareBelden Tofino Argon Fa-tsa-220-mm/tx Firmware+93/4/202217/6/2026
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
ModificadaAlta (7.5)1.00%—Belden Tofino Xenon Security Appliance FirmwareBelden Tofino Argon Fa-tsa-220-tx/mm FirmwareBelden Tofino Argon Fa-tsa-220-tx/tx FirmwareBelden Tofino Argon Fa-tsa-220-mm/tx Firmware+73/4/202217/6/2026
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.
ModificadaAlta (7.5)0.88%—Belden Tofino Xenon Security Appliance FirmwareBelden Tofino Argon Fa-tsa-220-tx/mm FirmwareBelden Tofino Argon Fa-tsa-220-tx/tx FirmwareBelden Tofino Argon Fa-tsa-220-mm/tx Firmware+73/4/202217/6/2026
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer.
ModificadaMedia (6.8)0.41%—Belden Tofino Xenon Security Appliance FirmwareBelden Tofino Argon Fa-tsa-220-tx/mm FirmwareBelden Tofino Argon Fa-tsa-220-tx/tx FirmwareBelden Tofino Argon Fa-tsa-220-mm/tx Firmware+93/4/202217/6/2026
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.
ModificadaMedia (5.5)0.44%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user…
ModificadaMedia (6.7)0.45%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
ModificadaMedia (6.5)1.2%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or…
ModificadaAlta (8.8)1.7%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated…
ModificadaCrítica (9.8)6.4%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an…
ModificadaMedia (5.9)0.86%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process Expert9/3/202217/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process…
ModificadaMedia (5.9)0.64%—Schneider-electric Ecostruxure Control Expert9/3/202217/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product:…