Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2687▼ 562 respecto a la semana anterior
Críticas / altas1259▼ 239 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)265▼ 239 respecto a la semana anterior
–

787 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)0.43%—Schneider-electric Ecostruxure Machine Expert - HvacSchneider-electric Somachine Hvac30/1/202317/6/2026
A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0)
ModificadaAlta (7.5)0.61%—Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 FirmwareSchneider-electric Modicon M340 Bmxp3420102 Firmware+1022/11/202217/6/2026
A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100…
ModificadaAlta (7.5)0.75%—Schneider-electric Modicon M340 BMX P34-2010 FirmwareSchneider-electric Modicon M340 BMX P34-2030 FirmwareSchneider-electric Modicon M580 Bmeh582040 FirmwareSchneider-electric Modicon M580 Bmeh582040c Firmware+4422/11/202217/6/2026
A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and…
ModificadaAlta (7.8)0.26%—Schneider-electric Ecostruxure Operator Terminal ExpertSchneider-electric Pro-face Blue4/11/202217/6/2026
A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected Products: EcoStruxure…
ModificadaAlta (7.8)0.20%—Schneider-electric Ecostruxure Operator Terminal ExpertSchneider-electric Pro-face Blue4/11/202217/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal…
ModificadaAlta (7.8)0.11%—Schneider-electric Ecostruxure Operator Terminal ExpertSchneider-electric Pro-face Blue4/11/202217/6/2026
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior),…
ModificadaAlta (7.8)0.21%—Schneider-electric Ecostruxure Operator Terminal ExpertSchneider-electric Pro-face Blue4/11/202217/6/2026
A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face…
ModificadaAlta (7.8)0.23%—Schneider-electric Ecostruxure Operator Terminal ExpertSchneider-electric Pro-face Blue4/11/202217/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior),…
ModificadaAlta (7.8)0.14%—Schneider-electric Ecostruxure Operator Terminal ExpertSchneider-electric Pro-face Blue4/11/202217/6/2026
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or…
ModificadaMedia (5.5)0.20%—Schneider-electric Ecostruxure Control Expert13/9/202217/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior).
ModificadaCrítica (9.8)0.77%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+3212/9/202217/6/2026
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control…
ModificadaMedia (5.3)0.57%—Schneider-electric OPC UA Module FOR M580 FirmwareSchneider-electric X80 Advanced RTU Module Firmware13/7/202217/6/2026
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100)…
ModificadaAlta (7.5)0.69%—Schneider-electric OPC UA Module FOR M580 FirmwareSchneider-electric X80 Advanced RTU Module Firmware13/7/202217/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)
ModificadaAlta (7.5)0.29%—Schneider-electric OPC UA Module FOR M580 FirmwareSchneider-electric X80 Advanced RTU Module Firmware13/7/202217/6/2026
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module…
ModificadaAlta (7.5)0.72%—Schneider-electric OPC UA Module FOR M580 FirmwareSchneider-electric X80 Advanced RTU Module Firmware13/7/202217/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA…
ModificadaAlta (7.5)0.89%—Schneider-electric OPC UA Module FOR M580 FirmwareSchneider-electric X80 Advanced RTU Module Firmware13/7/202217/6/2026
A CWE-476: NULL Pointer Dereference vulnerability exists that could cause a denial of service of the webserver when parsing JSON content type. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)
ModificadaAlta (7.5)0.78%—Schneider-electric OPC UA Module FOR M580 FirmwareSchneider-electric X80 Advanced RTU Module Firmware13/7/202217/6/2026
A CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop') vulnerability exists that could cause a denial of service of the webserver due to improper handling of the cookies. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10…
ModificadaAlta (7.5)0.78%—Schneider-electric OPC UA Module FOR M580 FirmwareSchneider-electric X80 Advanced RTU Module Firmware13/7/202217/6/2026
A CWE-787: Out-of-bounds Write vulnerability exists that could cause a denial of service of the webserver due to improper parsing of the HTTP Headers. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)
ModificadaMedia (4.9)0.45%—Schneider-electric Easergy P5 Firmware13/7/202217/6/2026
A CWE-20: Improper Input Validation vulnerability exists that could cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. Affected Products: Easergy P5 (V01.401.102 and prior)
ModificadaMedia (5.3)0.33%—Schneider-electric Easergy P5 Firmware13/7/202217/6/2026
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists where weak cipher suites can be used for the SSH connection between Easergy Pro software and the device, which may allow an attacker to observe protected communication details. Affected Products: Easergy P5 (V01.401.102 and prior)
ModificadaCrítica (9.8)1.6%—Schneider-electric Easergy P5 Firmware13/7/202217/6/2026
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior)
ModificadaMedia (6.8)0.30%—Schneider-electric Acti9 Powertag Link C (a9xelc10-a) FirmwareSchneider-electric Acti9 Powertag Link C (a9xelc10-b) Firmware13/7/202217/6/2026
A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior)
ModificadaAlta (8.8)70%💥 ExploitSchneider-electric Spacelogic C-bus Home Controller Firmware13/7/202217/6/2026
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460…
ModificadaAlta (7.8)0.44%—Schneider-electric GEO Scada Mobile24/6/202217/6/2026
A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)
ModificadaAlta (8.8)0.99%—Schneider-electric Wiser Smart Eer21000 FirmwareSchneider-electric Wiser Smart Eer21001 Firmware2/6/202217/6/2026
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)