Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas3008▲ 385 respecto a la semana anterior
Críticas / altas1453▲ 24 respecto a la semana anterior
Nueva explotación activa (KEV)6▼ 1 respecto a la semana anterior
Sin puntuar (sin CVSS)237▲ 223 respecto a la semana anterior
–

2279 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaCrítica (9.8)0.84%—Tenda AC8 Firmware24/8/202317/6/2026
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo.
ModificadaCrítica (9.8)1.2%—Tenda AC8 Firmware24/8/202317/6/2026
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
ModificadaCrítica (9.8)0.93%—Tenda AC8 Firmware24/8/202317/6/2026
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
ModificadaCrítica (9.8)0.84%—Tenda AC8 Firmware24/8/202317/6/2026
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.
ModificadaCrítica (9.8)0.93%—Tenda AC8 Firmware24/8/202317/6/2026
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
ModificadaCrítica (9.8)0.84%—Tenda AC8 Firmware24/8/202317/6/2026
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.
ModificadaCrítica (9.8)0.84%—Tenda AC8 Firmware24/8/202317/6/2026
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
ModificadaAlta (7.5)0.81%—Tenda AC8 Firmware21/8/20239/7/2026
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function.
ModificadaAlta (7.5)0.81%—Tenda AC8 Firmware21/8/20239/7/2026
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function.
ModificadaAlta (7.5)0.81%—Tenda AC8 Firmware21/8/20239/7/2026
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the save_virtualser_data function.
ModificadaCrítica (9.8)0.76%—Tenda Ac15 Firmware18/8/202317/6/2026
Se ha descubierto que Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 contiene un desbordamiento de búfer a través de la función FUN_00010e34().
ModificadaCrítica (9.8)0.76%—Tenda Wh450a Firmware18/8/202317/6/2026
Se ha descubierto que Tenda WH450 v1.0.0.18 contiene un desbordamiento de búfer a través de la función fgets.
ModificadaCrítica (9.8)0.76%—Tenda AC6 Firmware18/8/202317/6/2026
Se ha descubierto que Tenda AC6 _US_AC6V1.0BR_V15.03.05.16 contiene un desbordamiento de búfer a través de la función fgets.
ModificadaAlta (7.5)0.81%—Tenda A18 Firmware14/8/202317/6/2026
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function.
ModificadaAlta (7.5)0.81%—Tenda A18 Firmware14/8/202317/6/2026
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
ModificadaAlta (7.5)0.81%—Tenda A18 Firmware14/8/202317/6/2026
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function.
ModificadaCrítica (9.8)0.84%—Tenda Fh1203 FirmwareTenda F1203 FirmwareTenda Fh1205 Firmware7/8/202317/6/2026
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
ModificadaCrítica (9.8)0.84%—Tenda F1202 FirmwareTenda Fh1202 Firmware7/8/202317/6/2026
Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function.
ModificadaCrítica (9.8)0.84%—Tenda F1202 FirmwareTenda Pa202 FirmwareTenda Pw201a FirmwareTenda Fh1202 Firmware7/8/202317/6/2026
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im.
ModificadaCrítica (9.8)0.84%—Tenda Ac10 FirmwareTenda Ac1206 FirmwareTenda AC8 FirmwareTenda AC6 Firmware+37/8/202317/6/2026
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
ModificadaCrítica (9.8)0.85%—Tenda Ac10 FirmwareTenda Ac1206 FirmwareTenda AC6 FirmwareTenda AC7 Firmware+57/8/202317/6/2026
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
ModificadaCrítica (9.8)0.85%—Tenda Ac1206 FirmwareTenda AC5 FirmwareTenda AC9 FirmwareTenda AC8 Firmware+17/8/202317/6/2026
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
ModificadaCrítica (9.8)0.84%—Tenda Fh1203 FirmwareTenda F1203 FirmwareTenda Fh1205 Firmware7/8/202317/6/2026
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
ModificadaCrítica (9.8)0.84%—Tenda Ac10 FirmwareTenda Ac1206 FirmwareTenda AC6 FirmwareTenda AC7 Firmware+57/8/202317/6/2026
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
ModificadaCrítica (9.8)0.95%—Tenda F1202 FirmwareTenda Pa202 FirmwareTenda Pw201a FirmwareTenda Fh1202 Firmware7/8/202317/6/2026
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function.