Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2768▼ 428 respecto a la semana anterior
Críticas / altas1324▼ 116 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)265▼ 243 respecto a la semana anterior
139 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 1.1% | — | Tenda AC7 FirmwareTenda AC9 FirmwareTenda Ac10 FirmwareTenda Ac15 Firmware+1 | 29/10/2018 | 17/6/2026 | An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is… | |
| Modificada | Alta (7.5) | 1.1% | — | Tenda AC7 FirmwareTenda AC9 FirmwareTenda Ac10 FirmwareTenda Ac15 Firmware+1 | 29/10/2018 | 17/6/2026 | An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is… | |
| Modificada | Alta (7.5) | 1.4% | — | Tenda AC7 FirmwareTenda AC9 FirmwareTenda Ac10 FirmwareTenda Ac15 Firmware+1 | 29/10/2018 | 17/6/2026 | An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a… | |
| Modificada | Alta (7.5) | 1.1% | — | Tenda AC7 FirmwareTenda AC9 FirmwareTenda Ac10 FirmwareTenda Ac15 Firmware+1 | 29/10/2018 | 17/6/2026 | An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly… | |
| Modificada | Alta (7.5) | 1.1% | — | Tenda AC7 FirmwareTenda AC9 FirmwareTenda Ac10 FirmwareTenda Ac15 Firmware+1 | 29/10/2018 | 17/6/2026 | An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a… | |
| Modificada | Alta (8.8) | 3.6% | — | Tendacn Ac10 FirmwareTendacn AC9 Firmware | 2/9/2018 | 17/6/2026 | An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection. | |
| Modificada | Alta (7.5) | 1.7% | — | Tendacn Ac18 FirmwareTendacn Ac15 FirmwareTendacn Ac10 FirmwareTendacn AC9 Firmware+1 | 2/9/2018 | 17/6/2026 | An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server. While processing the ssid parameter for a POST request, the value is directly used in… | |
| Modificada | Alta (7.5) | 1.1% | — | Tendacn AC7 FirmwareTendacn AC9 FirmwareTendacn Ac10 FirmwareTendacn Ac15 Firmware+1 | 21/7/2018 | 17/6/2026 | Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. | |
| Modificada | Media (5.9) | 0.89% | — | Dell Idrac9 Firmware | 2/7/2018 | 17/6/2026 | Dell EMC iDRAC9 versions prior to 3.21.21.21 did not enforce the use of TLS/SSL for a connection to iDRAC web server for certain URLs. A man-in-the-middle attacker could use this vulnerability to strip the SSL/TLS protection from a connection between a client and a server. | |
| Modificada | Alta (8.8) | 3.4% | — | Dell Idrac7 FirmwareDell Idrac8 FirmwareDell Idrac9 Firmware | 2/7/2018 | 17/6/2026 | Dell EMC iDRAC7/iDRAC8, versions prior to 2.60.60.60, and iDRAC9 versions prior to 3.21.21.21 contain a command injection vulnerability in the SNMP agent. A remote authenticated malicious iDRAC user with configuration privileges could potentially exploit this vulnerability to execute arbitrary commands on the iDRAC… | |
| Modificada | Alta (7.5) | 1.8% | — | Dell Idrac6 FirmwareDell Idrac7 FirmwareDell Idrac8 FirmwareDell Idrac9 Firmware | 2/7/2018 | 17/6/2026 | Dell EMC iDRAC6, versions prior to 2.91, iDRAC7/iDRAC8, versions prior to 2.60.60.60 and iDRAC9, versions prior to 3.21.21.21, contain a weak CGI session ID vulnerability. The sessions invoked via CGI binaries use 96-bit numeric-only session ID values, which makes it easier for remote attackers to perform bruteforce… | |
| Modificada | Crítica (9.8) | 1.7% | — | Tendacn AC9 Firmware | 1/3/2018 | 17/6/2026 | Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact. | |
| Modificada | Media (6.5) | 1.0% | — | Tenda AC9 FirmwareTenda Ac15 FirmwareTenda Ac18 Firmware | 24/11/2017 | 17/6/2026 | Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn… | |
| Modificada | Alta (8.8) | 2.5% | — | Tenda AC9 FirmwareTenda Ac15 FirmwareTenda Ac18 Firmware | 21/11/2017 | 17/6/2026 | Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn… |