Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2856▼ 331 respecto a la semana anterior
Críticas / altas1383▼ 38 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)292▼ 217 respecto a la semana anterior
–

154 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)1.4%—Siemens Simatic Winac RTX (F) 201010/10/201917/6/2026
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions < SP3 Update 1). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is sent to the…
ModificadaAlta (7.5)4.1%—Microsoft Windows DefenderMicrosoft Forefront Endpoint Protection 2010Microsoft Security EssentialsMicrosoft System Center Endpoint Protection23/9/201917/6/2026
A denial of service vulnerability exists when Microsoft Defender improperly handles files, aka 'Microsoft Defender Denial of Service Vulnerability'.
ModificadaAlta (7.1)0.95%—Microsoft Windows DefenderMicrosoft Forefront Endpoint Protection 2010Microsoft Security EssentialsMicrosoft System Center Endpoint Protection14/8/201917/6/2026
An elevation of privilege vulnerability exists when the MpSigStub.exe for Defender allows file deletion in arbitrary locations. To exploit the vulnerability, an attacker would first have to log on to the system. An attacker could then run a specially crafted command that could exploit the vulnerability and delete…
ModificadaMedia (4.4)0.34%—Philips Zymed Holter 201024/7/201917/6/2026
Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled.
ModificadaMedia (5.5)0.68%—Hancom Office 2010Hancom Office 2014Hancom Office 2018Hancom Office NEO21/12/201817/6/2026
Hancom Office 2018 10.0.0.8214 and earlier, Hancom Office NEO 9.6.1.10472 and earlier, Hancom Office 2014 9.1.1.4540 and earlier, Hancom Office 2010 8.5.8.1724 and earlier versions have a heap overflow vulnerability when handling Compound File in document. This result in a program crash or denial of service conditions.
ModificadaMedia (5.4)2.3%—Microsoft Sharepoint Enterprise Server 2013Microsoft Sharepoint Enterprise Server 2016Microsoft Sharepoint Server 201013/9/201817/6/2026
A cross-site-scripting (XSS) vulnerability exists when Microsoft SharePoint Server does not properly sanitize a specially crafted web request to an affected SharePoint server, aka "Microsoft Office SharePoint XSS Vulnerability." This affects Microsoft SharePoint Server, Microsoft SharePoint.
ModificadaAlta (7.5)1.3%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
ModificadaCrítica (9.8)2.1%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
ModificadaCrítica (9.8)1.5%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.
ModificadaAlta (7.5)1.3%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.
ModificadaCrítica (9.8)1.9%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.
ModificadaCrítica (9.8)3.7%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
ModificadaAlta (8.8)19%—Microsoft Excel ServicesMicrosoft OfficeMicrosoft Office 2010Microsoft Office WEB Apps+212/4/201817/6/2026
A remote code execution vulnerability exists when the Office graphics component improperly handles specially crafted embedded fonts, aka "Microsoft Office Graphics Remote Code Execution Vulnerability." This affects Word, Microsoft Office, Microsoft SharePoint, Excel, Microsoft SharePoint Server.
ModificadaAlta (8.8)63%💥 ExploitMicrosoft Exchange ServerMicrosoft Security EssentialsMicrosoft Forefront Endpoint Protection 2010Microsoft Intune Endpoint Protection+24/4/201817/6/2026
A remote code execution vulnerability exists when the Microsoft Malware Protection Engine does not properly scan a specially crafted file, leading to memory corruption, aka "Microsoft Malware Protection Engine Remote Code Execution Vulnerability." This affects Windows Defender, Windows Intune Endpoint Protection,…
ModificadaMedia (6.5)0.54%—Siemens Simatic CP 343-1 FirmwareSiemens Simatic CP 443-1 FirmwareSiemens Simatic S7-1500 FirmwareSiemens Simatic S7-300 Firmware+720/3/201817/6/2026
A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants)…
ModificadaMedia (5.6)94%💥 ExploitIntel Atom CIntel Atom EIntel Atom X3Intel Atom X5-e3930+3044/1/201817/6/2026
Systems with microprocessors utilizing speculative execution and branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis.
ModificadaAlta (8.7)3.3%—Siemens Simatic S7-200 FirmwareSiemens Simatic S7-400pn V6 FirmwareSiemens Simatic S7-400h V6 FirmwareSiemens Simatic S7-400pn/dp V7 Firmware+3426/12/201717/6/2026
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
ModificadaAlta (7.5)14%—Microsoft Live MeetingMicrosoft LyncMicrosoft Office 2007Microsoft Office 2010+513/9/201717/6/2026
Windows Uniscribe in Microsoft Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Office 2007 SP3; Office 2010 SP2; Word Viewer; Office for Mac 2011 and 2016; Skype for Business 2016; Lync 2013 SP1; Lync 2010; Lync 2010 Attendee; and Live Meeting 2007 Add-in and Console allows an attacker to execute code remotely via…
ModificadaMedia (5.3)9.6%—Microsoft Live MeetingMicrosoft LyncMicrosoft OfficeMicrosoft Office 2007+1013/9/201717/6/2026
Windows Uniscribe in Microsoft Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; Windows 10 Gold, 1511, 1607, 1703, and Server 2016; Office 2007 SP3; Office 2010 SP2; Word Viewer; Office for Mac 2011 and 2016; Skype for Business 2016; Lync 2013 SP1; Lync…
ModificadaAlta (8.8)50%💥 ExploitMicrosoft Office 2007Microsoft Office 2010Microsoft Office Word ViewerMicrosoft Windows 10+613/9/201717/6/2026
Windows graphics on Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, and 1703, Windows Server 2016, Microsoft Office Word Viewer, Microsoft Office 2007 Service Pack 3 , and Microsoft Office 2010 Service Pack 2 allows…
ModificadaBaja (3.3)14%—Microsoft Live MeetingMicrosoft LyncMicrosoft OfficeMicrosoft Office 2007+1013/9/201717/6/2026
The Windows Graphics Device Interface (GDI) in Microsoft Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; Windows 10 Gold, 1511, 1607, 1703, and Server 2016; Office 2007 SP3; Office 2010 SP2; Word Viewer; Office for Mac 2011 and 2016; Skype for Business…
ModificadaAlta (7.5)4.8%—Schneider-electric Bmxnoc0401 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoe0110h Firmware+1130/6/201717/6/2026
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially…
ModificadaMedia (6.5)0.47%—Siemens PCS 7Siemens Primary Setup ToolSiemens Security Configuration ToolSiemens Simatic Automation Tool+1211/5/201717/6/2026
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions <…
AnalizadaCrítica (9.8)83%⚠ Explotación activa💥 ExploitNetgear D6100 FirmwareNetgear D7000 FirmwareNetgear D7800 FirmwareNetgear Jnr1010v2 Firmware+2430/1/201717/6/2026
The NETGEAR WNR2000v5 router contains a buffer overflow in the hidden_lang_avi parameter when invoking the URL /apply.cgi?/lang_check.html. This buffer overflow can be exploited by an unauthenticated attacker to achieve remote code execution.
ModificadaMedia (6.4)0.38%—Siemens Primary Setup ToolSiemens Security Configuration ToolSiemens Simatic IT Production SuiteSiemens Simatic NET PC Software+1415/11/201617/6/2026
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7…
Orbitaley — Vulnerabilidades