Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2860▼ 336 respecto a la semana anterior
Críticas / altas1383▼ 43 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)296▼ 214 respecto a la semana anterior
134 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (4.3) | 1.7% | — | Siemens Wincc | 8/4/2015 | 17/6/2026 | Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102. | |
| Modificada | Media (5) | 2.7% | — | Siemens Wincc | 18/2/2015 | 17/6/2026 | The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes… | |
| Modificada | Baja (1.9) | 0.36% | — | Siemens Simatic Wincc Sm@rtclient | 14/1/2015 | 17/6/2026 | The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism. | |
| Modificada | Baja (1.9) | 0.36% | — | Siemens Simatic Wincc Sm@rtclient | 14/1/2015 | 17/6/2026 | The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows local users to bypass an intended application-password requirement by leveraging the running of the app in the background state. | |
| Modificada | Baja (2.1) | 0.38% | — | Siemens Simatic Wincc Sm@rtclient | 14/1/2015 | 17/6/2026 | The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to extract the password from storage via unspecified vectors. | |
| Modificada | Media (5) | 2.0% | — | Siemens Simatic PCS 7Siemens Simatic Pcs7Siemens Simatic TiaportalSiemens Simatic Wincc | 26/11/2014 | 17/6/2026 | The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets. | |
| Modificada | Alta (10) | 5.3% | — | Siemens Simatic PCS 7Siemens Simatic Pcs7Siemens Simatic TiaportalSiemens Simatic Wincc | 26/11/2014 | 17/6/2026 | The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets. | |
| Modificada | Media (6.8) | 1.1% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of… | |
| Modificada | Media (4.6) | 0.36% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control. | |
| Modificada | Media (6) | 1.3% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433. | |
| Modificada | Media (4.9) | 1.2% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request. | |
| Modificada | Media (5) | 1.7% | — | Siemens Simatic Pcs7Siemens Wincc | 24/7/2014 | 17/6/2026 | The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request. | |
| Analizada | Alta (7.5) | 100% | ⚠ Explotación activa💥 Exploit | OpensslFilezilla-project Filezilla ServerSiemens Application Processing Engine FirmwareSiemens CP 1543-1 Firmware+24 | 7/4/2014 | 17/6/2026 | The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to… | |
| Modificada | Media (5) | 2.1% | — | Siemens Simatic Wincc Open Architecture | 7/2/2014 | 17/6/2026 | Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999. | |
| Modificada | Media (5) | 3.5% | — | Siemens Simatic Wincc Open Architecture | 7/2/2014 | 17/6/2026 | Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999. | |
| Modificada | Alta (7.5) | 5.3% | — | Siemens Simatic Wincc Open Architecture | 7/2/2014 | 17/6/2026 | The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999. | |
| Modificada | Media (5) | 1.7% | — | Siemens Simatic Wincc Open Architecture | 7/2/2014 | 17/6/2026 | Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack. | |
| Modificada | Media (5.8) | 2.1% | — | Siemens Wincc | 1/8/2013 | 16/6/2026 | Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product. | |
| Modificada | Media (6.8) | 1.1% | — | Siemens Wincc | 1/8/2013 | 16/6/2026 | Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product. | |
| Modificada | Media (4) | 1.3% | — | Siemens Simatic Pcs7Siemens Wincc | 14/6/2013 | 16/6/2026 | The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. | |
| Modificada | Alta (7.5) | 1.9% | — | Siemens Simatic Pcs7Siemens Wincc | 14/6/2013 | 16/6/2026 | The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. | |
| Modificada | Alta (7.5) | 1.8% | — | Siemens Simatic Pcs7Siemens Wincc | 14/6/2013 | 16/6/2026 | SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. | |
| Modificada | Media (4) | 2.3% | — | Siemens Simatic Pcs7Siemens Wincc | 21/3/2013 | 16/6/2026 | Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname. | |
| Modificada | Media (4) | 1.5% | — | Siemens Simatic Pcs7Siemens Wincc | 21/3/2013 | 16/6/2026 | Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query. | |
| Modificada | Media (5.8) | 1.9% | — | Siemens Simatic Pcs7Siemens Wincc | 21/3/2013 | 16/6/2026 | The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file. |