Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2704▼ 598 respecto a la semana anterior
Críticas / altas1288▼ 199 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)299▼ 211 respecto a la semana anterior
166 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (4.8) | 0.56% | — | Netgear D7800 FirmwareNetgear R7500v2 FirmwareNetgear R7800 FirmwareNetgear R8900 Firmware+13 | 30/12/2020 | 17/6/2026 | Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.68, R8900 before 1.0.4.28, R9000 before 1.0.4.28, RAX120 before 1.0.0.78, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK20 before 2.3.5.26, RBR20 before… | |
| Modificada | Media (4.8) | 0.56% | — | Netgear D7800 FirmwareNetgear R7500v2 FirmwareNetgear R7800 FirmwareNetgear R8900 Firmware+13 | 30/12/2020 | 17/6/2026 | Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.68, R8900 before 1.0.4.28, R9000 before 1.0.4.28, RAX120 before 1.0.0.78, RBK20 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before… | |
| Modificada | Media (4.8) | 0.66% | — | Netgear D7800 FirmwareNetgear R7500v2 FirmwareNetgear R7800 FirmwareNetgear R8900 Firmware+13 | 30/12/2020 | 17/6/2026 | Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.4.28, R9000 before 1.0.4.28, RAX120 before 1.0.0.78, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK20 before 2.3.5.26, RBR20 before… | |
| Modificada | Media (4.8) | 0.66% | — | Netgear D7800 FirmwareNetgear R7500v2 FirmwareNetgear R7800 FirmwareNetgear R8900 Firmware+7 | 30/12/2020 | 17/6/2026 | Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.4.28, R9000 before 1.0.4.28, RAX120 before 1.0.0.78, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, XR500 before 2.3.2.56, and XR700 before… | |
| Modificada | Media (4.8) | 0.56% | — | Netgear D7800 FirmwareNetgear R7500v2 FirmwareNetgear R7800 FirmwareNetgear R8900 Firmware+13 | 30/12/2020 | 17/6/2026 | Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.4.28, R9000 before 1.0.4.28, RAX120 before 1.0.0.78, RBK20 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before… | |
| Modificada | Crítica (9.4) | 1.6% | — | Netgear Ac2100 FirmwareNetgear Ac2400 FirmwareNetgear Ac2600 FirmwareNetgear Cbk40 Firmware+123 | 30/12/2020 | 17/6/2026 | Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D6000 before 1.0.0.80, D6220 before 1.0.0.60, D6400 before 1.0.0.94, D7000v2 before 1.0.0.62, D7800… | |
| Modificada | Crítica (9.8) | 1.2% | — | Netgear D3600 FirmwareNetgear D6000 FirmwareNetgear D6200 FirmwareNetgear D7000 Firmware+42 | 30/12/2020 | 17/6/2026 | Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.76, D6000 before 1.0.0.78, D6200 before 1.1.00.32, D7000 before 1.0.1.68, D7800 before 1.0.1.56, DM200 before 1.0.0.61, EX2700 before 1.0.1.52, EX6100v2 before 1.0.1.76, EX6150v2 before… | |
| Modificada | Crítica (9.8) | 1.2% | — | Netgear Ac2100 FirmwareNetgear Ac2400 FirmwareNetgear Ac2600 FirmwareNetgear Cbk40 Firmware+73 | 30/12/2020 | 17/6/2026 | Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D7800 before 1.0.1.58, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX7500 before 1.0.0.68, MK62… | |
| Modificada | Alta (8) | 0.49% | — | Netgear D3600 FirmwareNetgear D6000 FirmwareNetgear D6200 FirmwareNetgear D7000 Firmware+22 | 30/12/2020 | 17/6/2026 | Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D3600 before 1.0.0.76, D6000 before 1.0.0.76, D6200 before 1.1.00.36, D7000 before 1.0.1.70, EX6200v2 before 1.0.1.78, EX7000 before 1.0.1.78, EX8000 before 1.0.1.186, JR6150 before 1.0.1.18, PR2000 before 1.0.0.28, R6020… | |
| Modificada | Media (4.8) | 0.52% | — | Netgear D7800 FirmwareNetgear R7500v2 FirmwareNetgear R7800 FirmwareNetgear R8900 Firmware+7 | 9/10/2020 | 17/6/2026 | Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.68, R8900 before 1.0.4.28, R9000 before 1.0.4.28, RAX120 before 1.0.0.78, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, XR500 before 2.3.2.56, and XR700 before… | |
| Modificada | Media (6.8) | 0.63% | — | Netgear D6100 FirmwareNetgear R7800 FirmwareNetgear R8900 FirmwareNetgear R9000 Firmware+17 | 9/10/2020 | 17/6/2026 | Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.60, R8900 before 1.0.4.26, R9000 before 1.0.4.26, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32,… | |
| Modificada | Alta (7.5) | 1.2% | — | Mobile-industrial-robots Mir100 FirmwareMobile-industrial-robots Mir200 FirmwareMobile-industrial-robots Mir250 FirmwareMobile-industrial-robots Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | The Apache server on port 80 that host the web interface is vulnerable to a DoS by spamming incomplete HTTP headers, effectively blocking the access to the dashboard. | |
| Modificada | Crítica (9.8) | 0.97% | — | Aliasrobotics Mir100 FirmwareAliasrobotics Mir200 FirmwareAliasrobotics Mir250 FirmwareAliasrobotics Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | MiR robot controllers (central computation unit) makes use of Ubuntu 16.04.2 an operating system, Thought for desktop uses, this operating system presents insecure defaults for robots. These insecurities include a way for users to escalate their access beyond what they were granted via file creation, access race… | |
| Modificada | Media (4.6) | 0.97% | — | Aliasrobotics Mir100 FirmwareAliasrobotics Mir200 FirmwareAliasrobotics Mir250 FirmwareAliasrobotics Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | The BIOS onboard MiR's Computer is not protected by password, therefore, it allows a Bad Operator to modify settings such as boot order. This can be leveraged by a Malicious operator to boot from a Live Image. | |
| Modificada | Media (6.4) | 0.38% | — | Mobile-industrial-robots Mir100 FirmwareMobile-industrial-robots Mir200 FirmwareMobile-industrial-robots Mir250 FirmwareMobile-industrial-robots Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | There is no mechanism in place to prevent a bad operator to boot from a live OS image, this can lead to extraction of sensible files (such as the shadow file) or privilege escalation by manually adding a new user with sudo privileges on the machine. | |
| Modificada | Crítica (9.8) | 1.5% | — | Mobile-industrial-robots Mir100 FirmwareMobile-industrial-robots Mir200 FirmwareMobile-industrial-robots Mir250 FirmwareMobile-industrial-robots Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not… | |
| Modificada | Crítica (9.8) | 0.96% | — | Mobile-industrial-robots Mir100 FirmwareMobile-industrial-robots Mir200 FirmwareMobile-industrial-robots Mir250 FirmwareMobile-industrial-robots Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | The access tokens for the REST API are directly derived from the publicly available default credentials for the web interface. Given a USERNAME and a PASSWORD, the token string is generated directly with base64(USERNAME:sha256(PASSWORD)). An unauthorized attacker inside the network can use the default credentials to… | |
| Modificada | Alta (7.1) | 0.90% | — | Mobile-industrial-robots Mir100 FirmwareMobile-industrial-robots Mir200 FirmwareMobile-industrial-robots Mir250 FirmwareMobile-industrial-robots Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | The access tokens for the REST API are directly derived (sha256 and base64 encoding) from the publicly available default credentials from the Control Dashboard (refer to CVE-2020-10270 for related flaws). This flaw in combination with CVE-2020-10273 allows any attacker connected to the robot networks (wired or… | |
| Modificada | Alta (7.5) | 0.86% | — | Aliasrobotics Mir100 FirmwareAliasrobotics Mir200 FirmwareAliasrobotics Mir250 FirmwareAliasrobotics Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | MiR controllers across firmware versions 2.8.1.1 and before do not encrypt or protect in any way the intellectual property artifacts installed in the robots. This flaw allows attackers with access to the robot or the robot network (while in combination with other flaws) to retrieve and easily exfiltrate all installed… | |
| Modificada | Crítica (9.8) | 2.5% | — | Aliasrobotics Mir100 FirmwareAliasrobotics Mir200 FirmwareAliasrobotics Mir250 FirmwareAliasrobotics Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and… | |
| Modificada | Crítica (9.8) | 1.8% | — | Aliasrobotics Mir100 FirmwareAliasrobotics Mir200 FirmwareAliasrobotics Mir250 FirmwareAliasrobotics Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently,… | |
| Modificada | Crítica (9.8) | 1.7% | — | Aliasrobotics Mir100 FirmwareAliasrobotics Mir200 FirmwareAliasrobotics Mir250 FirmwareAliasrobotics Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also… | |
| Modificada | Crítica (9.8) | 1.4% | — | Aliasrobotics Mir100 FirmwareAliasrobotics Mir200 FirmwareAliasrobotics Mir250 FirmwareAliasrobotics Mir500 Firmware+6 | 24/6/2020 | 17/6/2026 | One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is… | |
| Modificada | Media (5.9) | 0.50% | — | Netgear R6120 FirmwareNetgear R6220 FirmwareNetgear R6350 FirmwareNetgear R6400 Firmware+10 | 28/5/2020 | 17/6/2026 | Certain NETGEAR devices are affected by Missing SSL Certificate Validation. This affects R7000 1.0.9.6_1.2.19 through 1.0.11.100_10.2.10, and possibly R6120, R7800, R6220, R8000, R6350, R9000, R6400, RAX120, R6400v2, RBR20, R6800, XR300, R6850, XR500, and R7000P. | |
| Modificada | Alta (8.8) | 0.51% | — | Commscope Ruckus Zoneflex R500 Firmware | 5/5/2020 | 17/6/2026 | CSRF in login.asp on Ruckus devices allows an attacker to access the panel, and use SSRF to perform scraping or other analysis via the SUBCA-1 field on the Wireless Admin screen. |