Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2730▼ 572 respecto a la semana anterior
Críticas / altas1301▼ 186 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)295▼ 215 respecto a la semana anterior
–

92 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)3.6%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+813/12/201817/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced…
ModificadaAlta (7.1)0.91%—Siemens Simatic CP 343-1 STD FirmwareSiemens Simatic CP 343-1 Lean FirmwareSiemens Simatic CP 343-1 ADV FirmwareSiemens Simatic CP 443-1 STD Firmware+7511/5/201717/6/2026
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
ModificadaAlta (7.1)1.1%—Siemens Simatic CP 343-1 STD FirmwareSiemens Simatic CP 343-1 Lean FirmwareSiemens Simatic CP 343-1 ADV FirmwareSiemens Simatic CP 443-1 STD Firmware+8911/5/201717/6/2026
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
ModificadaBaja (3.5)0.79%—Fieldable Panels Panes Project Fieldable Panels Panes17/9/201517/6/2026
The Fieldable Panels Panes module 7.x-1.x before 7.x-1.7 for Drupal does not properly check permissions to edit Fieldable Panels Panes entities, which allows remote authenticated users to edit panes by leveraging permissions to edit panels.
ModificadaAlta (8.5)12%💥 ExploitSiemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a…
ModificadaAlta (7.8)11%💥 ExploitSiemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows…
ModificadaAlta (7.1)7.3%💥 ExploitSiemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of…
ModificadaAlta (9.3)9.0%💥 ExploitSiemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote…
ModificadaAlta (9.3)14%💥 ExploitSiemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote…
ModificadaAlta (10)3.4%—Siemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access…
ModificadaAlta (10)4.8%—Siemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web…
ModificadaMedia (5)1.6%—Siemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to…
ModificadaMedia (4.3)1.4%—Siemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote…
ModificadaMedia (4.3)1.4%—Siemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote…
ModificadaAlta (10)2.0%—Siemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it…
ModificadaAlta (9.3)3.0%—Siemens Wincc FlexibleSiemens WinccSiemens Simatic HMI PanelsSiemens Wincc Runtime Advanced+13/2/201216/6/2026
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which…
ModificadaMedia (4.3)2.3%—Earl Miles Panels24/1/201216/6/2026
Cross-site scripting (XSS) vulnerability in display_renderers/panels_renderer_editor.class.php in the admin view in the Panels module 6.x-2.x before 6.x-3.10 and 7.x-3.x before 7.x-3.0 for Drupal allows remote authenticated users with certain privileges to inject arbitrary web script or HTML via the Region title.