Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2853▼ 343 respecto a la semana anterior
Críticas / altas1376▼ 50 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)339▼ 171 respecto a la semana anterior
156 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (8.1) | 13% | — | Netmotionsoftware Netmotion Mobility | 8/2/2021 | 17/6/2026 | NetMotion Mobility before 11.73 and 12.x before 12.02 allows unauthenticated remote attackers to execute arbitrary code as SYSTEM because of Java deserialization in RpcServlet. | |
| Modificada | Alta (8.1) | 41% | — | Netmotionsoftware Netmotion Mobility | 8/2/2021 | 17/6/2026 | NetMotion Mobility before 11.73 and 12.x before 12.02 allows unauthenticated remote attackers to execute arbitrary code as SYSTEM because of Java deserialization in SupportRpcServlet. | |
| Modificada | Media (6.8) | 1.1% | — | Schneider-electric Modicon M258 FirmwareSchneider-electric SomachineSchneider-electric Somachine Motion | 11/12/2020 | 17/6/2026 | A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not… | |
| Modificada | Alta (7.5) | 4.4% | — | Motion Project Motion | 26/10/2020 | 17/6/2026 | A Denial of Service condition in Motion-Project Motion 3.2 through 4.3.1 allows remote unauthenticated users to cause a webu.c segmentation fault and kill the main process via a crafted HTTP request. | |
| Modificada | Media (5.3) | 1.9% | — | Fanuc Series 30I FirmwareFanuc Series 31I FirmwareFanuc Series 32i-b Plus FirmwareFanuc Series 35i-b Firmware+12 | 3/8/2020 | 17/6/2026 | A denial-of-service vulnerability in the Fanuc i Series CNC (0i-MD and 0i Mate-MD) could allow an unauthenticated, remote attacker to cause an affected CNC to become inaccessible to other devices. | |
| Modificada | Alta (7.5) | 1.3% | — | Mitsubishielectric CPU Module Logging Configuration ToolMitsubishielectric CW ConfiguratorMitsubishielectric EM ConfiguratorMitsubishielectric GT Designer3+16 | 30/6/2020 | 17/6/2026 | Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier,… | |
| Modificada | Alta (7.5) | 1.4% | — | Mitsubishielectric CPU Module Logging Configuration ToolMitsubishielectric CW ConfiguratorMitsubishielectric EM ConfiguratorMitsubishielectric GT Designer3+16 | 30/6/2020 | 17/6/2026 | Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver.… | |
| Modificada | Media (5.5) | 0.54% | — | Intel Celeron 1000mIntel Celeron 1005mIntel Celeron 1007uIntel Celeron 1017u+690 | 15/6/2020 | 17/6/2026 | Incomplete cleanup from specific special register read operations in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. | |
| Modificada | Alta (7.5) | 0.88% | — | Schneider-electric Ecostruxure Machine ExpertSchneider-electric SomachineSchneider-electric Somachine MotionSchneider-electric Modicon M218 Firmware+3 | 22/4/2020 | 17/6/2026 | A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. | |
| Modificada | Crítica (9.8) | 0.69% | — | Schneider-electric Ecostruxure Machine ExpertSchneider-electric SomachineSchneider-electric Somachine MotionSchneider-electric Modicon M218 Firmware+3 | 22/4/2020 | 17/6/2026 | A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers. | |
| Modificada | Alta (7.5) | 1.4% | — | Siemens Cp1604 FirmwareSiemens Cp1616 FirmwareSiemens DK Standard Ethernet Controller FirmwareSiemens Ek-ertec 200 Firmware+36 | 10/10/2019 | 17/6/2026 | An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. | |
| Analizada | Crítica (9.8) | 73% | ⚠ Explotación activa💥 Exploit | Schneider-electric U.motion Builder | 22/5/2019 | 17/6/2026 | A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered. | |
| Modificada | Media (4.6) | 1.1% | 💥 PoC | HP 240 G1 FirmwareHP 245 G1 FirmwareHP 1000-1300 FirmwareHP 250 G1 Notebook PC Firmware+30 | 3/10/2018 | 17/6/2026 | A BIOS password extraction vulnerability has been reported on certain consumer notebooks with firmware F.22 and others. The BIOS password was stored in CMOS in a way that allowed it to be extracted. This applies to consumer notebooks launched in early 2014. | |
| Modificada | Media (5.3) | 1.1% | — | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request. | |
| Modificada | Media (6.1) | 0.75% | — | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts. | |
| Modificada | Crítica (9.8) | 3.0% | — | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass. | |
| Modificada | Crítica (9.8) | 2.3% | — | Schneider-electric U.motion | 3/7/2018 | 17/6/2026 | In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application. | |
| Modificada | Alta (8.8) | 32% | 💥 Exploit | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server. | |
| Modificada | Media (4.3) | 0.68% | — | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data. | |
| Modificada | Alta (8.8) | 0.97% | — | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the username input parameter. | |
| Modificada | Alta (8.8) | 0.97% | — | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | The vulnerability exists within processing of nfcserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the sessionid input parameter. | |
| Modificada | Alta (8.8) | 0.97% | — | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | The vulnerability exists within processing of applets which are exposed on the web service in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query to determine whether a user is logged in is subject to SQL injection on the loginSeed parameter, which can be… | |
| Modificada | Alta (8) | 1.4% | — | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | The vulnerability exists within processing of editscript.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A directory traversal vulnerability allows a caller with standard user privileges to write arbitrary php files anywhere in the web service directory tree. | |
| Modificada | Media (6.5) | 1.3% | — | Schneider-electric U.motion | 3/7/2018 | 17/6/2026 | The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address. | |
| Modificada | Alta (8.8) | 0.97% | — | Schneider-electric U.motion Builder | 3/7/2018 | 17/6/2026 | The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter. |